Parte de libro

Calvo, E.J.; Otero, M. "Chemical sensors" (2008) Piezoelectric Transducers and Applications:241-257
La versión final de este artículo es de uso interno de la institución.
Consulte el artículo en la página del editor

Abstract:

We are surrounded by a complex environment and therefore need to monitor aspects of this environment in real time in connection with pollution, health and safety, etc. Like the human senses of olfaction, sight, touch, hearing and taste link us with the external world, chemical sensors allow us to monitor and record the chemical variables of the external environment in the same way we monitor temperature, pressure, etc. A chemical sensor is a device which responds to a particular analyte molecule in a selective way in the presence of other molecules through a chemical reaction and can be used for the qualitative and quantitative determination of the analyte in the complex sample. After recognition of a molecular entity, the chemical sensor transduces the signal through a physicochemical process into an electrical signal which can be further amplified and processed. While Chap. 2 deals with different types of acoustic transducers, this tutorial focuses on the chemical sensing layer that affects the molecular re ognition and the different transducers that can be employed. Different types of chemical sensors include different transducing methods to obtain processable electrical signals, so we have a variety of chemical sensors: 1. Electrochemical (potential, current or conductivity). 2. Optical (optical waves). 3. Mass sensitive (acoustic wave sensing). 4. Heat (calorimetric). 5. Magnetic. The present trend is to integrate the chemical sensor with microelectronics and sample handling. This has led to impressive achievements in miniaturization using silicon micromachining methods and more recently soft lithography techniques [1, 2]. In addition, the recent explosive growth of microfluidics [3] has allowed liquid samples to be transferred by electrophoretic driving forces into contact with an array of chemical microsensors giving rise to the concept of lab-on-chip. This is a fully integrated chemical laboratory in a microchip with applications as wide as health care and remote medicine, environmental control and food analysis. Applications in the area of explosive early detection, chemical and biological warfare has recently emerged as a fast growing field. Patients requiring rapid blood analyses in emergency rooms, intensive or critical care units as well as in the operating theatres can undergo rapid blood tests with only a few drops of whole blood with the point-of-care systems. In 1985 Dr. I. Lauks developed the I-Stat point-of-care blood analysis system [4]. It comprises a single-use cartridge containing an array of electrochemical sensors capable of measuring blood oxygen, CO2 and pH. Also it measures electrolytes such as potasium, sodium, chloride, calcium ions, glucose, urea nitrogen and hematocrit in few minutes with only a few drops of whole blood. The development of I-Stat was made possible by the incorporation of microfabrication techniques from the microelectronic industry in a 5 x 4 mm chip. There are also examples of commercial systems to monitor glucose in a tiny drop of whole blood of a Diabetes Mellitus pa ient. Glucose levels in the clinical range 20-600 ng dL-1 can now be measured in 20 seconds with a drop from 0.3 to 3.5 μL of whole blood using commercial integrated chemical sensors [5, 6]. Implantable glucose sensors have also been developed. An alternative novel way of chemical sensors is the electronic nose [7]. This olfaction machine is an electronic device capable of detecting and recognizing complex odors. Unlike molecular recognition, electronic noses work on the principle of multiple signal detection and pattern recognition. The signal can be generated by chemical detection interfaces with changes of conductivity of a solid state or conducting polymer prompted by the interaction of analyte molecules from a complex sample. The signal transduction can be affected by a variety of physicochemical processes, i.e. metal-oxide gas sensors, conducting polymer gas sensors, bulk and surface acoustic wave gas sensors, field effect chemo-transistors, electrochemical gas sensors, etc. They are normally used in a ultisensor array to generate a signal pattern. The recognition is not selective at the molecular identity but rather to a signal pattern recognition and multicomponent analysis. It can be applied to health care or food analysis, i.e., to very complex samples such as coffee, beer, wine, etc., freshness of fish or to smell a cow to determine its health status. The signal generation can be affected by electrochemical, electrical (resistance), acoustic (bulk acoustic and surface waves), etc. processes, normally with an array of detectors (metal oxide or conducting polymer detectors) each one slightly different from the rest. The general requirements that a chemical sensor must fulfill are: 1. Sensitivity The limit of detection of a given substance is related to the minimum concentration capable of producing a signal that can be discriminated from the noise level (i.e. by the signal-to-noise ratio) and the sensitivity is related to the slope of a signal-to-concentration plot at a given concentration. It is desirable that such a sensor response plot be linear. 2. Selectivity High selectivity is needed to discriminate qualitatively and quantitatively a given component in a complex sample matrix, i.e., detection of glucose in whole blood where other molecules like ascorbate, urate, etc., may interfere. Selectivity can be achieved by molecular recognition, i.e., by molecular shape as key and lock problem or by pattern recognition when a complex pattern of transduced signals is obtained like in electronic noses. 3. Stability The molecules that comprise the chemical recognition interface may not be stable enough and the chemical sensor response decays with time. If the inventory of chemo-receptor or molecules that recognize the analyte is not in excess with respect to the stoichiometric value-which happens when the sensing response is determined by kinetics-then the stability is a critical factor to guarantee a reproducible response. On the other hand, if the signal is determined by mass transport of the analyte, the de ay in sensing molecules should not be determining. © Springer-Verlag Berlin Heidelberg 2008.

Registro:

Documento: Parte de libro
Título:Chemical sensors
Autor:Calvo, E.J.; Otero, M.
Filiación:Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires, Buenos Aires, Argentina
Año:2008
Página de inicio:241
Página de fin:257
DOI: http://dx.doi.org/10.1007/978-3-540-77508-9_9
Título revista:Piezoelectric Transducers and Applications
Título revista abreviado:Piezoelectric Transducers and Applic.
Registro:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_97835407_v_n_p241_Calvo

Referencias:

  • Turner, A.P.F., Karube, I., Wilson, G.S., (1987) Biosensors: Fundamentals and Applications, 770p. , Oxford University Press, Oxford
  • Clark Jr., L.C., Monitor and control of blood and tissue oxygen tensions (1956) Trans. Am. Soc. Artif. Intern. Organs, 2, pp. 41-48
  • Clark Jr., L.C., Lyons, C., Electrode systems for continuous monitoring in cardiovascular surgery (1962) Ann. N.Y. Acad. Sci., 105, pp. 29-45
  • Updike, S.J., Hicks, G.P., The enzyme electrode (1967) Nature, 214, pp. 986-988
  • Guilbault, G.G., Montalvo, J., Urea specific enzyme electrode (1969) JACS, 91, pp. 2164-2569
  • Ramsay, G., Commercial biosensors. Applications to clinical, bioprocesses, and environmental samples (1998) Series of Monographs on Analytical Chemistry, 48. , J. Wiley & Sons, New York
  • Cooney, C.L., Weaver, J.C., Tannebaum, S.R., Faller, S.R., Shields, D.V., Jahnke, M., Thermal enzymes probe: A novel approach to chemical analysis (1974) Enzyme Engineering, 2, pp. 411-417. , (Eds. E.K. Pye and L.B. Wingard Jnr.) Plenum, New York
  • Mosbach, K., Danielsson, B., An enzyme thermistor 1974) (1974) Biochim. Biophys. Acta, 364, pp. 140-145
  • Diviés, C., Remarques sur l'oxydation de l'éthanol par une electrode microbienne d'acetobacter zylinum (1975) Ann. Microbiol, 126 A, pp. 175-186
  • Lubbers, D.W., Opitz, N., The pco2-/po2-optode: A new probe for measurement of pco2 or po2 in fluids and gases" (in german) (1975) Z. Naturforsch. C: Biosci, 30 C, pp. 532-533
  • Voelkl, K.P., Opitz, N., Lubbers, D.W., Continuous measurement of concentrations of alcohol using a fluorescence-photometric enzymatic method (1980) Fres. Z. Anal. Chem., 301, pp. 162-163
  • Clemens, A.H., Chang, P.H., Myers, R.W., Development of an automatic system of insulin infusion controlled by blood sugar, its system for the determination of glucose and control algorithms (1976) Proceedings of Journees annuelles de diabetologie de l.Hotel-Dieu, pp. 269-278. , Paris
  • Shichiri, M., Kawamori, R., Yamaski, R., Hakai, Y., Abe, H., Wearable artificial endocrine pancreas with needle-type glucose sensor (1982) Lancet, 2, pp. 1129-1131
  • Liedberg, B., Nylander, C., Lundstrm, I., Surface plasmon resonance for gas detection and biosensing (1983) Sensors and Actuators, 4, pp. 299-304
  • Cass, A.E.G., Davis, G., Francis, G.D., Hill, H.A.O., Aston, W.J., Higgina, I.J., Plotkin, E.V., Turner, A.P.F., Ferrocene-mediated enzyme electrode for amperometric determination of glucose (1984) Anal. Chem., 56, pp. 666-671
  • Alberts, B., Johnson, A., Lewis, J., Raff, M., Roberts, K., Walter, P., (2002) Molecular biology of the cell, , 4th edn. Garland Science, New York
  • Calvo, E.J., Danilowicz, C., Wolosiuk, A., Molecular "wiring enzymes in organized nanostructures (2002) J. Am. Chem. Soc, 124, pp. 2452-2453
  • Chaki, N.K., Vijayamohanan, K., Self-Assembled monolayers as a tunable platform for biosensor applications (2002) Biosensors & Bioelectronics, 17, pp. 1-12

Citas:

---------- APA ----------
Calvo, E.J. & Otero, M. (2008) . Chemical sensors. Piezoelectric Transducers and Applications, 241-257.
http://dx.doi.org/10.1007/978-3-540-77508-9_9
---------- CHICAGO ----------
Calvo, E.J., Otero, M. "Chemical sensors" . Piezoelectric Transducers and Applications (2008) : 241-257.
http://dx.doi.org/10.1007/978-3-540-77508-9_9
---------- MLA ----------
Calvo, E.J., Otero, M. "Chemical sensors" . Piezoelectric Transducers and Applications, 2008, pp. 241-257.
http://dx.doi.org/10.1007/978-3-540-77508-9_9
---------- VANCOUVER ----------
Calvo, E.J., Otero, M. Chemical sensors. Piezoelectric Transducers and Applic. 2008:241-257.
http://dx.doi.org/10.1007/978-3-540-77508-9_9