Artículo

Estamos trabajando para incorporar este artículo al repositorio
Consulte la política de Acceso Abierto del editor

Abstract:

The placement of an implantable cardiac device (ICD), either a pacemaker, an implantable cardioverter defibrillator or a device for cardiac resynchronization therapy is an increasingly common practice in heart failure patients. Within these ICD technological advances is the possibility of monitoring ST segment changes. Continuous ST-segment monitoring via intracardiac electrogram is predicated on the understanding that acute ST changes are frequently correlated with clinically significant coronary events. ST-segment monitoring via Holter ECGs have proven useful for patients who are asymptomatic with coronary syndromes which include coronary artery disease (CAD), acute myocardial infarction, unstable angina, as well as symptomatic patients with a nondiagnostic ECG (no-ST elevation) from standard diagnostic electrocardiograms. Concluding that for patients with CAD, especially post-myocardial infarction, ST segment monitoring can play an important role. ©2013 Silver Horse.

Registro:

Documento: Artículo
Título:Chronic ST-segment monitoring via the intracardiac electrogram for implantable cardiac device
Autor:Bevacqua, R.J.
Filiación:Médico cardiólogo. División Cardiología, Pabellón Inchauspe. Hospital General de Agudos 'Dr. J. M. Ramos Mejía', GCBA, Ciudad de Buenos Aires, Argentina
Palabras clave:Continuous monitoring; Coronary artery disease; Electrocardiogram; Heart failure; Implantable cardiac device; Intracardiac electrogram; ST segment
Año:2013
Volumen:8
Número:1
Página de inicio:31
Página de fin:40
Título revista:Insuficiencia Cardiaca
Título revista abreviado:Insuficiencia Cardiaca
ISSN:18501044
Registro:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_18501044_v8_n1_p31_Bevacqua

Referencias:

  • Poole, J.E., Johnson, G.W., Hellkamp, A.S., Anderson, J., Callans, D.J., Raitt, M.H., Reddy, R.K., Marchlinski, F.E., Prognostic importance of defibrillator shocks in patients with heart failure (2008) N Engl J Med, 359, pp. 1009-1017
  • Bardy, G.H., Lee, K.L., Mark, D.B., Poole, J.E., Fishbein, D.P., Sudden Cardiac Death-Heart Failure Trial (SCD-HeFT) (2000) Arrhythmia treatment and therapy, pp. 323-342. , SCDHeFT Investigators, In: Woosley RL, Singh SN, eds, New York: Marcel Dekker
  • Bardy, G.H., Lee, K.L., Mark, D.B., Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure (2005) N Engl J Med, 352, pp. 225-237
  • Moss, A.J., Zareba, W., Hall, W.J., Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction (2002) N Engl J Med, 346, pp. 877-883
  • (2008) J Am Coll Cardiol, 51, pp. 2085-2105. , ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices) developed in collaboration with the American Association for Thoracic Surgery and Society of Thoracic Surgeons
  • Conolly, S.J., Hallstrom, B., Cappato, S., Meta-analysis of the implantable cardioverter secondary prevention trials (2000) Eur Heart J, 21, pp. 2071-2078
  • Moss, A.J., Zareba, W., Hall, W.J., Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction (2002) N Engl J Med, 346, pp. 877-883
  • Cannom, D.S., Prystowsky, E.N., Management of ventricular arrhythmias detection, drugs and devices (1999) JAMA, 281, pp. 172-179
  • Pires, L.A., Lehmann, M.H., Steinmann, R.T., Sudden death in implantable cardioverter-defibrillator recipients: Clinical context, arrhythmic events and device responses (1999) J Am Coll Cardiol, 33, pp. 24-32
  • Waters, D., Timothy, E.C., Lesperance, J., Prognostic significance of progression of coronary atherosclerosis (1993) Circulation, 87, pp. 1067-1075
  • Moise, A., Bourassa, M.G., Theroux, P., Prognostic significance of progression of coronary artery disease (1985) Am J Cardiol, 55, pp. 941-948
  • Bousfield, G., Changes in electrocardiogram during paroxysm (1918) Lancet, 2, p. 475
  • Feil, H., Siegel, M., Electrocardiographic changes during attacks of angina pectoris (1928) Am J Med Sci, 175, pp. 255-260
  • Blackburn, H., Katigbak, R., What electrocardiographic leads to take after exercise? (1964) Am Heart J, 67, pp. 184-185
  • Sketch, M.H., Nair, C.K., Esterbrooks, D.J., Reliability of single-lead and multiple-lead electrocardiography during and after exercise (1978) Chest, 74, pp. 394-401
  • Mason, R.E., Likar, I., Biern, R.O., Multiple-lead exercise electrocardiography. Experience in 107 normal subjects and 67 patients with angina pectoris, and comparison with coronary cinearteriography in 84 patients (1967) Circulation, 36, pp. 517-525
  • Gibbons, R.J., (2002) ACC/AHA 2002 Guideline Update for Exercise Testing, , ACC/AHA
  • Holter, N., Gengerelli, J., Remote recording of physiological data by radio (1949) Rocky Mountain Medical Journal, 46, pp. 749-752
  • Corday, E., Bazika, V., Lang, T.W., Detection of phantom arrhythmias and evanescent electrocardiographic Abnormalities: Use of Prolonged Direct Electrocardiocording (1965) JAMA, 193, pp. 417-421
  • Stern, S., Tzivoni, D., Early detection of silent ischaemic heart disease by 24-hour electrocardiographic monitoring of active subjects (1974) Br Heart J, 36, pp. 481-486
  • Asbach, S., Weiss, I., Wenzel, B., Intrathoracic far-field electrocardiogram allows continuous monitoring of ischemia after total coronary occlusion (2006) Pacing Clin Electrophysiol, 29, pp. 1334-1340
  • Fischell, T.A., Fischell, D.R., Fischell, R.E., Real-time detection and alerting for acute ST-segment elevation myocardial ischemia using an implantable, high-fidelity, intracardiac electrogram monitoring system with long-range telemetry in an ambulatory porcine model (2006) J Am Coll Cardiol, 48, pp. 2306-2314
  • Fischell, T.A., Fischell, D.R., Fischell, R.E., Potential of an intracardiac electrograma for the rapid detection of coronary artery occlusion (2005) Cardiovasc Revasc Med, 6, pp. 14-20
  • Baron, T.W., Faber, T.S., Grom, A., Real-time assessment of acute myocardial ischaemia by an intra-thoracic 6-lead ECG: Evaluation of a new diagnostic option in the implantable defibrillator (2006) Europace, 8, pp. 994-1001
  • Theres, H., Stadler, R.W., Stylos, L., Comparison of electrocardiogram and intrathoracic electrogram signals for detection of ischemic ST segment changes during normal sinus and ventricular paced rhythms (2002) J Cardiovasc Electrophysiol, 13, pp. 990-995
  • Varriale, P., Niznik, J., Unipolar ventricular electrogram in the diagnosis of right ventricular ischemic injury (1978) Pacing Clin Electrophysiol, 1, pp. 335-341
  • Siegel, S., Brodman, R., Fisher, J., Intracardiac electrode detection of early or subendocardial ischemia (1982) Pacing Clin Electrophysiol, 5, pp. 892-902
  • Hoberg, E., Schuler, G., Kunze, B., Silent myocardial ischemia as a potential link between lack of premonitoring symptoms and increased risk of cardiac arrest during physical stress (1990) Am J Cardiol, 65, pp. 583-589
  • Durakovic, Z., Misigoj-Durakovic, M., Skavic, J., Sudden death due to recreational exercise in physicians (2002) Coll Antropol, 26, pp. 509-513
  • Niebauer, J., Hambrecht, R., Hauer, K., Identification of patients at risk during swimming by Holter monitoring (1994) Am J Cardiol, pp. 651-656
  • Soufer, R., Bremner, J.D., Arrighi, J.A., Cerebral cortical hyperactivation in response to mental stress in patients with coronary artery disease (1998) Proc Natl Acad Sci U S A, 95, pp. 6454-6459
  • Rozanski, A., Bairey, C., Krantz, D., Mental stress and the induction of silent myocardial ischemia in patients with coronary artery disease (1988) N Engl J Med, 318, pp. 1005-1012
  • Jiang, W., Babyak, M., Krantz, D.S., Mental stress-induced myocardial ischemia and cardiac events (1996) JAMA, 275, pp. 1651-1656
  • Carels, R.A., Sherwood, A., Babyak, M., Emotional responsivity and transient myocardial ischemia (1999) J Consult Clin Psychol, 67, pp. 605-610
  • Papageorgiou, C., Anthopoulos, L., Mitsimbounas, D., Relation of personality and emotional factors to myocardial ischemia, methodology and first observations (1981) Psychother Psychosom, 36, pp. 92-97
  • Shi, R.Y., Bai, H.Z., Chen, Y.X., Influence of emotional stress and behavior during acute myocardial infarction on prognosis (1989) Zhonghua Nei Ke Za Zhi, 28, pp. 212-215+251
  • Dimsdale, J.E., Emotional causes of sudden death (1977) Am J Psychiatry, 134, pp. 1361-1366
  • Hunziker, P.R., Gradel, C., Muller-Brand, J., Improved myocardial ischemia detection by combined physical and mental stress testing (1998) Am J Cardiol, 82, pp. 109-113
  • Suzuki, M., Hirayama, T., Marumoto, K., Paroxysmal atrial fibrillation as a cause of potentially lethal ventricular arrhythmia with myocardial ischemia in hypertrophic cardiomyopathy--a case report (1998) Angiology, 49, pp. 653-657
  • Pedersen, O.D., Abildstrom, S.Z., Ottesen, M.M., Increased risk of sudden and non-sudden cardiovascular death in patients with atrial fibrillation/flutter following acute myocardial infarction (2006) Eur Heart J, 27, pp. 290-295
  • Hagens, V.E., Rienstra, M., Van Veldhuisen, D.J., Determinants of sudden cardiac death in patients with persistent atrial fibrillation in the rate control versus electrical cardioversion (RACE) study (2006) Am J Cardiol, 98, pp. 929-932
  • Stone, P.H., Chaitman, B.R., McMahon, R.P., Asymptomatic Cardiac Ischemia Pilot (ACIP) Study. Relationship between exercise-induced and ambulatory ischemia in patients with stable coronary disease (1996) Circulation, 94, pp. 1537-1544
  • Stone, P.H., ST-segment analysis in ambulatory ECG (AECG or Holter) monitoring in patients with coronary artery disease: Clinical significance and analytic techniques (2005) Ann Noninvasive Electrocardiol, 10, pp. 263-278
  • Kleiner, J.P., Nelson, W.P., Boland, M.J., The 12-lead electrocardiogram in exercise testing (1978) A misleading baseline? Arch Intern Med, 138, pp. 1572-1573
  • Deedwania, P.C., Carbajal, E.V., Usefulness of ambulatory silent myocardial ischemia added to the prognostic value of exercise test parameters in predicting risk of cardiac death in patients with stable angina pectoris and exercise-induced myocardial ischemia (1991) Am J Cardiol, 68, pp. 1279-1286
  • Yeung, A.C., Vekshtein, V.I., Krantz, D.S., The effect of atherosclerosis on the vasomotor response of coronary arteries to mental stress (1991) N Engl J Med, 325, pp. 1551-1556
  • Davies, R.F., Habibi, H., Klinke, W.P., Effect of amlodipine, atenolol and their combination on myocardial ischemia during treadmill exercise and ambulatory monitoring. Canadian Amlodipine/Atenolol in Silent Ischemia Study (CASIS) Investigators (1995) J Am Coll Cardiol, 25, pp. 619-625
  • Parmley, W.W., Nesto, R.W., Singh, B.N., Attenuation of the circadian patterns of myocardial ischemia with nifedipine GITS in patients with chronic stable angina. N-CAP Study Group (1992) J Am Coll Cardiol, 19, pp. 1380-1389
  • von Arnim, T., Medical treatment to reduce total ischemic burden: Total ischemic burden bisoprolol study (TIBBS), a multicenter trial comparing bisoprolol and nifedipine. The TIBBS Investigators (1995) J Am Coll Cardiol, 25, pp. 231-238
  • de Lemos, J.A., Braunwald, E., ST segment resolution as a tool for assessing the efficacy of reperfusion therapy (2001) J Am Coll Cardiol, 38, pp. 1283-1294
  • Krucoff, M.W., Croll, M.A., Pope, J.E., Continuous 12-lead STsegment recovery analysis in the TAMI 7 study. Performance of a noninvasive method for real-time detection of failed myocardial reperfusion (1993) Circulation, 88, pp. 437-446
  • Roe, M.T., Green, C.L., Giugliano, R.P., Improved speed and stability of ST-segment recovery with reduced-dose tenecteplase and eptifibatide compared with full-dose tenecteplase for acute ST-segment elevation myocardial infarction (2004) J Am Coll Cardiol, 43, pp. 549-556
  • Patel, D.J., Gomma, A.H., Knight, C.J., Why is recurrent myocardial ischaemia a predictor of adverse outcome in unstable angina? An observational study of myocardial ischaemia and its relation to coronary anatomy (2001) Eur Heart J, 22, pp. 1991-1996
  • Zairis, M.N., Ambrose, J.A., Papadaki, O.A., C-reactive protein and ST-segment monitoring by continuous 12-lead electrocardiogram in patients with primary unstable angina pectoris (2003) Am J Cardiol, 91, pp. 600-603
  • Jernberg, T., Lindahl, B., Wallentin, L., ST-segment monitoring with continuous 12-lead ECG improves early risk stratification in patients with chest pain and ECG nondiagnostic of acute myocardial infarction (1999) J Am Coll Cardiol, 34, pp. 1413-1419
  • Biagini, E., Schinkel, A.F.L., Bax, J.J., Long term outcome in patients with silent versus symptomatic ischaemia during dobutamine stress echocardiography (2005) Heart, 91, pp. 737-742
  • Hirzel, H.O., Leutwyler, R., Krayenbuehl, H.P., Silent myocardial ischemia: Hemodynamic changes during dynamic exercise in patients with proven coronary artery disease despite absence of angina pectoris (1985) J Am Coll Cardiol, 6, pp. 275-284

Citas:

---------- APA ----------
(2013) . Chronic ST-segment monitoring via the intracardiac electrogram for implantable cardiac device . Insuficiencia Cardiaca, 8(1), 31-40.
Recuperado de https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_18501044_v8_n1_p31_Bevacqua [ ]
---------- CHICAGO ----------
Bevacqua, R.J. "Chronic ST-segment monitoring via the intracardiac electrogram for implantable cardiac device " . Insuficiencia Cardiaca 8, no. 1 (2013) : 31-40.
Recuperado de https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_18501044_v8_n1_p31_Bevacqua [ ]
---------- MLA ----------
Bevacqua, R.J. "Chronic ST-segment monitoring via the intracardiac electrogram for implantable cardiac device " . Insuficiencia Cardiaca, vol. 8, no. 1, 2013, pp. 31-40.
Recuperado de https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_18501044_v8_n1_p31_Bevacqua [ ]
---------- VANCOUVER ----------
Bevacqua, R.J. Chronic ST-segment monitoring via the intracardiac electrogram for implantable cardiac device . Insuficiencia Cardiaca. 2013;8(1):31-40.
Available from: https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_18501044_v8_n1_p31_Bevacqua [ ]