Conferencia

Graf, S.; Craiem, D.; Valero, M.; Alfonso, M.; Barra, J.G.; Armentano, R.L. "Estudio de la variabilidad de las propiedades mecánicas arteriales en 24 horas: Prueba preliminar en oveja consciente" (2013) 5th Latin American Congress on Biomedical Engineering, CLAIB 2011. 33 IFMBE:798-801
Estamos trabajando para incorporar este artículo al repositorio
Consulte el artículo en la página del editor
Consulte la política de Acceso Abierto del editor

Abstract:

Previous studies in animals, showed a different behavior between the variability of arterial pressure, arterial diameter and arterial elasticity when they were recorded during a couple of hours. On this basis, we proposed to advance in the simultaneous measurement of pressure and diameter of a central artery for 24 hours and provide new hypotheses on the variability of mechanical properties throughout the day.We have recently developed a prototype of an autonomous and portable device that allows continuous acquisition of physio- logical signals throughout the day, storing them in solid state memory for later analysis. In this paper we present the used methodology and the tuning of the implemented system, and first results obtained by recording continuously for 24 hours in a sheep, signals of pressure and aortic diameter, as well as pulse wave velocity as an indicator of arterial stiffness. © 2013 Springer.

Registro:

Documento: Conferencia
Título:Estudio de la variabilidad de las propiedades mecánicas arteriales en 24 horas: Prueba preliminar en oveja consciente
Autor:Graf, S.; Craiem, D.; Valero, M.; Alfonso, M.; Barra, J.G.; Armentano, R.L.
Ciudad:Habana
Filiación:Fac. de Ingeniería Y Ciencias Exactas Y Naturales, Universidad Favaloro, Buenos Aires, Argentina
Dto. de Ciencias Fisiológicas, Universidad Favaloro, Buenos Aires, Argentina
CONICET, Buenos Aires, Argentina
Palabras clave:Aortic Diameter; Arterial diameter; Arterial pressures; Arterial stiffness; Logical signals; Pulse wave velocity; Simultaneous measurement; Solid state memory; Elasticity; Biomedical engineering
Año:2013
Volumen:33 IFMBE
Página de inicio:798
Página de fin:801
DOI: http://dx.doi.org/10.1007/978-3-642-21198-0_203
Título revista:5th Latin American Congress on Biomedical Engineering, CLAIB 2011
Título revista abreviado:IFMBE Proc.
ISSN:16800737
Registro:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_16800737_v33IFMBE_n_p798_Graf

Referencias:

  • Armentano, R.L., Barra, J.G., Levenson, J., Simon, A., Pichel, R., Arterial wall mechanics in conscious dogs: Assessment of viscous, inertial, and elastic moduli to characterize aortic wall behavior (1995) Circulation Research, 76 (3), pp. 468-478
  • Gamero, L.G., Armentano, R.L., Levenson, J., Arterial wall diameter and viscoelasticity variability (2002) Computers in Cardiology, 29, pp. 513-516
  • Craiem, D., Graf, S., Salvucci, F., Chironi, G., Megnien, J.L., Simon, A., Armentano, R.L., Physiological principles of the ambulatory arterial stiffness index explained by the non-linearity of arterial elasticity (2010) Physiological Measurements, 31 (7), pp. 1037-1046
  • Alfonso, M., (2009) Sistema Portable para El Cálculo Y Registro de Parámetros Fisiológicos, , Tesis de grado. FICEN. Universidad Favaloro
  • Chiu, C.Y., Arand, P.W., Shroff, A., Feldman, T., Carroll, J., Determination of pulse wave velocities with computerized algorithms (1991) Am Heart J, 121, p. 146
  • Valero, M., Craiem, D., Caputo, J.M., Guzman, G., Graf, S., Armentano, R.L., Simulación de la influencia de la elasticidad parietal sobre el índice ambulatorio de rigidez arterial AASI (2009) Revista Colombiana Ingeniería Biomédica, 3 (6), pp. 18-25A4 - SKAN AG; Materialise NV; Bavarian Minist. Econ., Aff., Infrastruct., Transp. Technol.; Bavarian Bureau for International Business Relations GmbH; AKUD - Med Pharm GmbH

Citas:

---------- APA ----------
Graf, S., Craiem, D., Valero, M., Alfonso, M., Barra, J.G. & Armentano, R.L. (2013) . Estudio de la variabilidad de las propiedades mecánicas arteriales en 24 horas: Prueba preliminar en oveja consciente. 5th Latin American Congress on Biomedical Engineering, CLAIB 2011, 33 IFMBE, 798-801.
http://dx.doi.org/10.1007/978-3-642-21198-0_203
---------- CHICAGO ----------
Graf, S., Craiem, D., Valero, M., Alfonso, M., Barra, J.G., Armentano, R.L. "Estudio de la variabilidad de las propiedades mecánicas arteriales en 24 horas: Prueba preliminar en oveja consciente" . 5th Latin American Congress on Biomedical Engineering, CLAIB 2011 33 IFMBE (2013) : 798-801.
http://dx.doi.org/10.1007/978-3-642-21198-0_203
---------- MLA ----------
Graf, S., Craiem, D., Valero, M., Alfonso, M., Barra, J.G., Armentano, R.L. "Estudio de la variabilidad de las propiedades mecánicas arteriales en 24 horas: Prueba preliminar en oveja consciente" . 5th Latin American Congress on Biomedical Engineering, CLAIB 2011, vol. 33 IFMBE, 2013, pp. 798-801.
http://dx.doi.org/10.1007/978-3-642-21198-0_203
---------- VANCOUVER ----------
Graf, S., Craiem, D., Valero, M., Alfonso, M., Barra, J.G., Armentano, R.L. Estudio de la variabilidad de las propiedades mecánicas arteriales en 24 horas: Prueba preliminar en oveja consciente. IFMBE Proc. 2013;33 IFMBE:798-801.
http://dx.doi.org/10.1007/978-3-642-21198-0_203