Artículo

Diaz, S.; Booth, C.R.; Armstrong, R.; Brunat, C.; Cabrera, S.; Camilion, C.; Casiccia, C.; Deferrari, G.; Fuenzalida, H.; Lovengreen, C.; Paladini, A.; Pedroni, J.; Rosales, A.; Zagarese, H.; Vernet, M. "Multichannel radiometer calibration: A new approach" (2005) Applied Optics. 44(26):5374-5380
Estamos trabajando para incorporar este artículo al repositorio
Consulte el artículo en la página del editor
Consulte la política de Acceso Abierto del editor

Abstract:

The error in irradiance measured with Sun-calibrated multichannel radiometers may be large when the solar zenith angle (SZA) increases. This could be particularly detrimental in radiometers installed at mid and high latitudes, where SZAs at noon are larger than 50° during part of the year. When a multi-regressive methodology, including the total ozone column and SZA, was applied in the calculation of the calibration constant, an important improvement was observed. By combining two different equations, an improvement was obtained at almost all the SZAs in the calibration. An independent test that compared the irradiance of a multichannel instrument and a spectroradiometer installed in Ushuaia, Argentina, was used to confirm the results. © 2005 Optical Society of America.

Registro:

Documento: Artículo
Título:Multichannel radiometer calibration: A new approach
Autor:Diaz, S.; Booth, C.R.; Armstrong, R.; Brunat, C.; Cabrera, S.; Camilion, C.; Casiccia, C.; Deferrari, G.; Fuenzalida, H.; Lovengreen, C.; Paladini, A.; Pedroni, J.; Rosales, A.; Zagarese, H.; Vernet, M.
Filiación:Centro Austral de Investigaciones Científicas (CADIC), Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), B. Houssay 200, 9410, Ushuaia, Argentina
Biospherical Instruments Inc., 5340 Riley Street, San Diego, CA 92110-2621, United States
Universidad de Puerto Rico, P.O. Box 3202, Lajas, 00667-3202, Puerto Rico
CADIC, Inter American Institute for Global Change Research (IAI), B. Houssay 200, 9410, Ushuaia, Argentina
Universidad de Chile, Casilla 70061, Correo 7, Santiago, Chile
CADIC, National Science Foundation, IAI, B. Houssay 200, 9410, Ushuaia, Argentina
Universidad de Magallanes, Laboratorio de Ozono y RUV, Casilla 113-D, Punta Arenas, Chile
Universidad de Chile, Departamento de Geofisica, Casilla 2777, Santiago, Chile
Universidad Austral de Chile, Facultad de Ciencias, Ed. Emilio Pugin, Casilla 567, Valdivia, Chile
Instituto de Investigaciones en Ingenieria Genética y Biologia Molecular, CONICET, Obligado 2490, 1428 Buenos Aires, Argentina
Universidad de la Patagonia San Juan Bosco, Departamento Física, Gales 50, 9100 Trelew, Argentina
Instituto Tecnológico de Chascomús, CONICET, Laboratorio de Ecología y Fotobiología Acuática, CC 164, Chascomús, Argentina
Scripps Institution of Oceanography, Integrative Oceanography Division, University of California, San Diego, San Diego, CA 92093-0218, United States
Palabras clave:Calibration; Error analysis; Irradiation; Ozone; Solar energy; Sun; Calibration constant; Ozone column; Radiometer calibration; Solar zenith angle (SZA); Radiometers
Año:2005
Volumen:44
Número:26
Página de inicio:5374
Página de fin:5380
DOI: http://dx.doi.org/10.1364/AO.44.005374
Título revista:Applied Optics
Título revista abreviado:Appl. Opt.
ISSN:1559128X
CODEN:APOPA
Registro:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_1559128X_v44_n26_p5374_Diaz

Referencias:

  • Hoiskar, B.A.K., Haugen, R., Danielsen, T., Kylling, A., Edvarsen, K., Dahlback, A., Johnsen, A., Schreder, J., Multichannel moderate-bandwidth filter instrument for measurement of the ozone-column amount, cloud transmittance, and ultraviolet dose rates (2003) Appl. Opt., 42, pp. 3472-3479
  • Schmid, B., Wehrli, C., Comparison of Sun photometer calibrations by use of the Langley technique and the standard lamp (1995) Appl. Opt., 34, pp. 4500-4512
  • Slusser, J., Gibson, J., Bigelow, D., Kolinski, D., Disterhoft, P., Lantz, K., Beaubien, A., Langley method of calibrating UV filter radiometers (2000) J. Geophys. Res., 105, pp. 4841-4849
  • Ingold, T., Mätzler, C., Wehrli, C., Heimo, A., Kämpfer, N., Philipona, R., Ozone column density determination from direct irradiance measurements in the ultraviolet performed by a four-channel precision filter radiometer (2001) Appl. Opt., 40, pp. 1989-2003
  • Booth, C.R., Mestechkina, T., Morrow, J.H., Errors in the reporting of solar spectral irradiance using moderate band-width radiometers: An experimental investigation (1994) Proc. SPIE, 2258, pp. 654-663. , Ocean Optics XII, J. S. Jaffe, ed
  • Dahlback, A., Measurements of biologically effective UV doses, total ozone abundance, and cloud effects with multichannel moderate bandwidth filter instruments (1996) Appl. Opt., 35, pp. 6514-6521
  • Fuenzalida, H.A., Global ultraviolet spectra derived directly from observations with multichannel radiometers (1998) Appl. Opt., 37, pp. 7912-7919
  • Diaz, S.B., Nelson, D., Deferrari, G., Camilion, C., A model to extend spectral and multiwavelength UV irradiances time series. Model development and validation (2003) J. Geophys. Res., [Atmos.], 108, p. 4150
  • Diaz, S., Booth, C., Deferrari, G., Camilion, C., Robertson, J., Improving multichannel radiometer calibration and data quality (2002) Proc. SPIE, 4815, pp. 90-96. , Atmospheric Radiation Measurements and Applications in Climate, J. E. Shaw, ed
  • Diaz, S., Booth, R., Armstrong, R., Cabrera, S., Casiccia, C., Fuenzalida, H., Lovengreen, C., Vernet, M., Calibration improvement of the LAI Network for the measurement of UVR: Multichannel instruments (2003) Proc. SPIE, 4896, pp. 106-113. , Ultraviolet Ground- and Space-based Measurements, Models, and Effects II, W. Gao, J. R. Herman, G. Shi, K. Shibasaki, and J. R. Slusser, eds
  • Booth, C.R., Lucas, T.B., Morrow, J.H., Weiler, C.S., Penhale, P.A., The United States National Science Foundation's Polar Network for monitoring ultraviolet radiation (1994) Antarctic Research Series, 62, pp. 17-37. , Ultraviolet Radiation in Antarctica: Measurements and Biological Effects, C. S. Weiler and P. A. Penhale, eds. (American Geophysical Union)
  • Thorseth, T.M., Kjeldstad, B., Comparison of solar UV measurements performed with spectroradiometer and moderate bandwidth multichannel radiometer for different cloud conditions (2000) J. Geophys. Res., 105, pp. 4809-4820

Citas:

---------- APA ----------
Diaz, S., Booth, C.R., Armstrong, R., Brunat, C., Cabrera, S., Camilion, C., Casiccia, C.,..., Vernet, M. (2005) . Multichannel radiometer calibration: A new approach. Applied Optics, 44(26), 5374-5380.
http://dx.doi.org/10.1364/AO.44.005374
---------- CHICAGO ----------
Diaz, S., Booth, C.R., Armstrong, R., Brunat, C., Cabrera, S., Camilion, C., et al. "Multichannel radiometer calibration: A new approach" . Applied Optics 44, no. 26 (2005) : 5374-5380.
http://dx.doi.org/10.1364/AO.44.005374
---------- MLA ----------
Diaz, S., Booth, C.R., Armstrong, R., Brunat, C., Cabrera, S., Camilion, C., et al. "Multichannel radiometer calibration: A new approach" . Applied Optics, vol. 44, no. 26, 2005, pp. 5374-5380.
http://dx.doi.org/10.1364/AO.44.005374
---------- VANCOUVER ----------
Diaz, S., Booth, C.R., Armstrong, R., Brunat, C., Cabrera, S., Camilion, C., et al. Multichannel radiometer calibration: A new approach. Appl. Opt. 2005;44(26):5374-5380.
http://dx.doi.org/10.1364/AO.44.005374