Artículo

Comastri, S.A.; Bastida, K.; Bianchetti, A.; Perez, L.I.; Pérez, G.D.; Martin, G. "Zernike aberrations when pupil varies: Selection rules, missing modes and graphical method to identify modes" (2009) Journal of Optics A: Pure and Applied Optics. 11(8)
Estamos trabajando para incorporar este artículo al repositorio
Consulte el artículo en la página del editor
Consulte la política de Acceso Abierto del editor

Abstract:

Aberrations of the eye and other image-forming systems are often analyzed by expanding the wavefront aberration function for a given pupil in Zernike polynomials. In previous articles explicit analytical formulae to transform Zernike coefficients of up to seventh order corresponding to wavefront aberrations for an original pupil into those related to a contracted transversally displaced new pupil are obtained. In the present paper, selection rules for the direct and inverse coefficients' transformation are given and missing modes associated with certain displacement directions are analyzed. Taking these rules into account, a graphical method to qualitatively identify which are the elements of the transformation matrix and their characteristic dependence on pupil parameters is presented. This method is applied to fictitious systems having only one non-zero original coefficient and, for completeness, the new coefficient values are also analytically evaluated. © 2009 IOP Publishing Ltd.

Registro:

Documento: Artículo
Título:Zernike aberrations when pupil varies: Selection rules, missing modes and graphical method to identify modes
Autor:Comastri, S.A.; Bastida, K.; Bianchetti, A.; Perez, L.I.; Pérez, G.D.; Martin, G.
Filiación:Grupo de Ptica y Visión, Departamento de Física, Universidad de Buenos Aires, (C1063ACV) Buenos Aires, Argentina
Consejo Nacional de Investigaciones Científicas y Técnicas, (C1033AAJ) Buenos Aires, Argentina
Laboratorio de Ptica y Dimensional, Departamento de Física y Metrología, Instituto Nacional de Tecnología Industrial, (B1650WAB) Buenos Aires, Argentina
Reichert Incorporated, 3362 Walden Avenue, Depew, NY 14127, United States
Palabras clave:Ocular aberrations; Pupil size and centring; Zernike coefficients; Analytical formulas; Coefficient values; Displacement direction; Graphical methods; Image-forming systems; Ocular aberrations; Pupil size and centring; Selection Rules; Transformation matrices; Wavefront aberrations; Zernike aberrations; Zernike coefficient; Zernike coefficients; Zernike polynomials; Graphic methods; Three term control systems; Wavefronts; Aberrations
Año:2009
Volumen:11
Número:8
DOI: http://dx.doi.org/10.1088/1464-4258/11/8/085302
Título revista:Journal of Optics A: Pure and Applied Optics
Título revista abreviado:J Opt A Pure Appl Opt
ISSN:14644258
CODEN:JOAOF
Registro:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_14644258_v11_n8_p_Comastri

Referencias:

  • Born, M., Wolf, E., (1987) Principles of Optics
  • Smith, W.J., (1966) Modern Optical Engineering
  • Thibos, L.N., A VSIA-sponsored effort to develop methods and standards for the comparison of the wave-front aberration structure of the eye between devices and laboratories (1999) Vision Sciences and Its Applications 1, pp. 236-239
  • Wilson, M., Campbell, M., Simonet, P., Changes of pupil centration with change of illumination and pupil size (1992) Opt. Vis. Sci., 69 (2), pp. 129-136
  • Artal, P., Marcos, S., Iglesias, I., Green, D.G., Optical modulation transfer and contrast sensitivity with decentered small pupils in the human eye (1996) Vis. Res., 36 (22), pp. 3575-3586
  • Applegate, R.A., Thibos, L.N., Bradley, A., Marcos, S., Roorda, A., Salmon, T.O., Atchison, D.A., Reference axis selection: Subcommittee report of the OSA working group to establish standards for measurement and reporting of optical aberrations of the eye (2000) J. Refract. Surg., 16, pp. 656-658
  • Liang, J., Williams, D.R., Aberrations and retinal image quality of the normal human eye (1997) J. Opt. Soc. Am., 14 (11), pp. 2873-2883
  • Tabernero, J., Benito, A., Alcón, E., Artal, P., Mechanism of compensation of aberrations in the human eye (2007) J. Opt. Soc. Am., 24 (10), pp. 3274-3283
  • Guirao, A., Gonzalez, C., Redondo, M., Geragbty, E., Norrby, S., Artal, P., Average optical performance of the human eye as a function of age in a normal population (1999) Inv. Opt. Vis. Sci., 40, pp. 203-213
  • Porter, J., Guirao, A., Cox, I.G., Williams, D., Monochromatic aberrations of the human eye in a large population (2001) J. Opt. Soc. Am., 18 (8), pp. 1793-1803
  • Marcos, S., Barbero, S., Llorente, L., Merayo-Lloves, J., Optical response to myopic LASIK surgery from total and corneal aberration measurements (2001) Inv. Ophthalmol. Vis. Sci., 42, pp. 3349-3356
  • Barbero, S., Marcos, S., Merayo-Lloves, J., Moreno Barriuso, E., Validation of the estimation of corneal aberrations from videokeratography in Keratoconus (2002) J. Refract. Surg., 18, pp. 263-269
  • Guirao, A., Williams, D.R., Cox, I.G., Effect of rotation and translation on the expected benefit of an ideal method to correct the eye's higher order aberrations (2001) J. Opt. Soc. Am., 18 (5), pp. 1003-1015
  • Schwiegerling, J., Scaling Zernike expansion coefficients to different pupil sizes (2002) J. Opt. Soc. Am., 19 (10), pp. 1937-1945
  • Campbell, C.E., Matrix method to find a new set of Zernike coefficients from an original set when the aperture radius is changed (2003) J. Opt. Soc. Am., 20 (2), pp. 209-217
  • Bara, S., Arines, J., Ares, J., Prado, P., Direct transformation of Zernike eye aberration coefficients between scaled, rotated and/or displaced pupils (2006) J. Opt. Soc. Am., 23 (9), pp. 2061-2066
  • Lundström, L., Unsbo, P., Transformation of Zernike coefficients: Scaled, translated and rotated wavefronts with circular and elliptical pupils (2007) J. Opt. Soc. Am., 24 (3), pp. 569-577
  • Comastri, S.A., Perez, L.I., Pérez, G.D., Martin, G., Bastida, K., Zernike expansion coefficients: Rescaling and decentring for different pupils and evaluation of corneal aberrations (2007) J. Opt. A: Pure Appl. Opt., 9 (3), pp. 209-221
  • Comastri, S.A., Perez, L.I., Pérez, G.D., Bastida, K., Martin, G., Wavefront aberrations: Analytical method to convert Zernike coefficients from a pupil to a scaled arbitrarily decentered one (2008) Proc. Am. Inst. Phys., 992, pp. 69-74
  • Comastri, S.A., Pérez, G.D., Martin, G., Bianchetti, A., Corneal Zernike aberrations for different pupils: Precision in the parameters and applications (2008) Pt. Pura Apl., 41, pp. 367-380

Citas:

---------- APA ----------
Comastri, S.A., Bastida, K., Bianchetti, A., Perez, L.I., Pérez, G.D. & Martin, G. (2009) . Zernike aberrations when pupil varies: Selection rules, missing modes and graphical method to identify modes. Journal of Optics A: Pure and Applied Optics, 11(8).
http://dx.doi.org/10.1088/1464-4258/11/8/085302
---------- CHICAGO ----------
Comastri, S.A., Bastida, K., Bianchetti, A., Perez, L.I., Pérez, G.D., Martin, G. "Zernike aberrations when pupil varies: Selection rules, missing modes and graphical method to identify modes" . Journal of Optics A: Pure and Applied Optics 11, no. 8 (2009).
http://dx.doi.org/10.1088/1464-4258/11/8/085302
---------- MLA ----------
Comastri, S.A., Bastida, K., Bianchetti, A., Perez, L.I., Pérez, G.D., Martin, G. "Zernike aberrations when pupil varies: Selection rules, missing modes and graphical method to identify modes" . Journal of Optics A: Pure and Applied Optics, vol. 11, no. 8, 2009.
http://dx.doi.org/10.1088/1464-4258/11/8/085302
---------- VANCOUVER ----------
Comastri, S.A., Bastida, K., Bianchetti, A., Perez, L.I., Pérez, G.D., Martin, G. Zernike aberrations when pupil varies: Selection rules, missing modes and graphical method to identify modes. J Opt A Pure Appl Opt. 2009;11(8).
http://dx.doi.org/10.1088/1464-4258/11/8/085302