Artículo

Bia, D.; Pessana, F.; Armentano, R.; Pérez, H.; Graf, S.; Zócalo, Y.; Saldías, M.; Perez, N.; Alvarez, O.; Silva, W.; Machin, D.; Sueta, P.; Ferrin, S.; Acosta, M.; Alvarez, I. "Cryopreservation procedure does not modify human carotid homografts mechanical properties: An isobaric and dynamic analysis" (2006) Cell and Tissue Banking. 7(3):183-194
Estamos trabajando para incorporar este artículo al repositorio
Consulte el artículo en la página del editor
Consulte la política de Acceso Abierto del editor

Abstract:

The viscoelastic and inertial properties of the arterial wall are responsible for the arterial functional role in the cardiovascular system. Cryopreservation is widely used to preserve blood vessels for vascular reconstruction but it is controversially suspected to affect the dynamic behaviour of these allografts. The aim of this work was to assess the cryopreservation's effects on human arteries mechanical properties. Common carotid artery (CCA) segments harvested from donors were divided into two groups: Fresh (n = 18), tested for 24-48 h after harvesting, and Cryopreserved (n = 18) for an average time of 30 days in gas-nitrogen phase, and finally defrosted. Each segment was tested in a circulation mock, and its pressure and diameter were registered at similar pump frequency, pulse and mean pressure levels, including those of normotensive and hipertensive conditions. A compliance transfer function (diameter/pressure) derived from a mathematical adaptive modelling was designed for the on line assessment of the arterial wall dynamics and its frequency response. Assessment of arterial wall dynamics was made by measuring its viscous (η), inertial (M) and elastic (E) properties, and creep and stress relaxation time constant (τC and τSR, respectively). The frequency response characterization allowed to evaluate the arterial wall filter or buffer function. Results showed that non-significant differences exist between wall dynamics and buffer function of fresh and cryopreserved segments of human CCA. In conclusion, our cryopreservation method maintains arterial wall functional properties, close to their fresh values. © Springer 2006.

Registro:

Documento: Artículo
Título:Cryopreservation procedure does not modify human carotid homografts mechanical properties: An isobaric and dynamic analysis
Autor:Bia, D.; Pessana, F.; Armentano, R.; Pérez, H.; Graf, S.; Zócalo, Y.; Saldías, M.; Perez, N.; Alvarez, O.; Silva, W.; Machin, D.; Sueta, P.; Ferrin, S.; Acosta, M.; Alvarez, I.
Filiación:Departamento de Fisiología, Facultad de Medicina, Universidad de la República, General Flores 2125, Montevideo PC:11800, Uruguay
Facultad de Ingeniería y Ciencias Exactas y Naturales, Universidad Favaloro, Solís 453, C1078AAI Buenos Aires, Argentina
Banco Nacional de Órganos y Tejidos, Ministerio de Salud Pública, Facultad de Medicina, Montevideo, Uruguay
Facultad de Medicina, Universidad de la Républica, Hospital de Clínicas, Avenida Italia 2870, PC: 11600 Montevideo, Uruguay
Idioma: Inglés
Palabras clave:Arterial wall; Cryopreservation; Human arteries; Pressure-diameter; Viscoelasticity; nitrogen; arterial pressure; artery diameter; artery graft; artery wall; article; biomechanics; blood vessel function; common carotid artery; controlled study; cryopreservation; gas; graft preservation; human; human tissue; priority journal; pulse pressure; stress; thawing; viscoelasticity; Carotid Arteries; Cryopreservation; Elasticity; Humans; Transplantation, Homologous
Año:2006
Volumen:7
Número:3
Página de inicio:183
Página de fin:194
DOI: http://dx.doi.org/10.1007/s10561-005-0655-0
Título revista:Cell and Tissue Banking
Título revista abreviado:Cell Tissue Bank.
ISSN:13899333
CODEN:CTBAF
CAS:nitrogen, 7727-37-9
Registro:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_13899333_v7_n3_p183_Bia

Referencias:

  • Adham, M., Gournier, J.P., Favre, J.P., La, E., Roche, C., Ducerf, J., Baulieux Barral, X., Pouyet, M., Mechanical characteristics of fresh and frozen human descending thoracic aorta (1996) J. Surg. Res. 15, 64 (1), pp. 32-34. , 1:STN:280:BymH3c%2FgvFA%3D 10.1006/jsre.1996.0302
  • Akaike, H., Fitting autoregressive models for prediction (1969) Ann. Inst. Stat. Math., 21, pp. 243-247
  • Alvarez, I., DelCarmen Saldias, M., Wodowoz, O., Perez Campos, H., Machin, D., Silva, W., Sueta, P., AcostaMd Mdel, C., Progress of national multi-tissue bank in uruguay in the international atomic energy agency (IAEA) tissue banking programme (2003) Cell Tissue Bank, 4 (2-4), pp. 173-178. , 15256857 10.1023/B:CATB.0000007036.45040.20
  • Armentano, R.L., Barra, J.G., Levenson, J., Simon, A., Pichel, R.H., Assessment of viscous, inertial, and elastic moduli to characterize aortic wall behavior (1995) Circ. Res., 76 (3), pp. 468-478. , Arterial wall mechanics in conscious dogs 1:CAS:528:DyaK2MXkt1Wrsr8%3D
  • Armentano, R., Megnien, J.L., Simon, A., Bellenfant, F., Barra, J., Levenson, J., Effects of hypertension on viscoelasticity of carotid and femoral arteries in humans (1995) Hypertension, 26 (1), pp. 48-54. , 1:STN:280:ByqA3s7osFw%3D
  • Armentano, R.L., Bia, D., Craiem, D., Gamero, L., Levenson, J., Grignola, J.C., Ginés, F.F., Respuesta en frecuencia de la pared arterial: Inocente o culpable de las discrepancias entre filtrado sistémico y pulmonar? (2003) Rev. Mex. Ing. Biom., 24 (1), pp. 45-54
  • Bia, D., Armentano, R.L., Grignola, J.C., Craiem, D., Zocalo, Y.A., Gines, F.F., Levenson, J., The vascular smooth muscle of great arteries: Local control site of arterial buffering function? (2003) Rev. Esp. Cardiol., 56 (12), pp. 1202-1209. , 14670273 10.1157/13055339
  • Bia, D., Armentano, R., Craiem, D., Grignola, J., Gines, F., Simon, A., Levenson, J., Smooth muscle role on pulmonary arterial function during acute pulmonary hypertension in sheep (2004) Acta Physiol. Scand, 181 (3), pp. 359-366. , 15196096 1:CAS:528:DC%2BD2cXlslSqtrw%3D 10.1111/j.1365-201X.2004.01294.x
  • Bia Santana, D., Barra, J.G., Grignola, J.C., Gines, F.F., Armentano, R.L., Pulmonary artery smooth muscle activation attenuates arterial dysfunction during acute pulmonary hypertension (2005) J Appl Physiol, 98 (2), pp. 605-613. , Feb; doi:1011152/jappliedphysiol.00361.2004]. Epub 2004, Oct. 15
  • Blondel, W., Lehalle, B., Maurice, G., Wang, X., Stoltz, J.F., Rheological properties of fresh and cryopreserved human arteries tested in vitro (2000) Rheol. Acta, 39 (5), pp. 461-468. , 1:CAS:528:DC%2BD3cXotV2mt7o%3D 10.1007/s003970000110
  • Bujan, J., Pascual, G., Lopez, R., Corrales, C., Rodriguez, M., Turegano, F., Bellon, J.M., Gradual thawing improves the preservation of cryopreserved arteries (2001) Cryobiology, 42 (4), pp. 256-265. , 11748934 1:STN:280:DC%2BD38%2Fgt1Gnuw%3D%3D 10.1006/cryo.2001.2329
  • Dawber, R., Cold kills! (1988) Clin. Exp. Dermatol., 13 (3), pp. 137-150. , 3073026 1:STN:280:BiaB3s%2FnvFU%3D 10.1111/j.1365-2230.1988.tb01958.x
  • Fischer, E.I., Armentano, R.L., Pessana, F.M., Graf, S., Romero, L., Christen, A.I., Simon, A., Levenson, J., Endothelium-dependent arterial wall tone elasticity modulated by blood viscosity (2002) Am. J. Physiol. Heart Circ. Physiol., 282 (2), pp. H389-H394. , 11788384 1:CAS:528:DC%2BD38XhtFCqsLo%3D
  • Fahy, G.M., Lilley, T.H., Linsdell, H., Douglas, M.S., Meryman, H.T., Cryoprotectant toxicity and cryoprotectant toxicity reduction: In search of molecular mechanisms (1990) Cryobiology, 27 (3), pp. 247-268. , 2199153 1:CAS:528:DyaK3cXkvFChur8%3D 10.1016/0011-2240(90)90025-Y
  • Fahy, G.M., Levy, D.I., Ali, S.E., Some emerging principles underlying the physical properties, biological actions, and utility of vitrification solutions (1987) Cryobiology, 24 (3), pp. 196-213. , 3595164 1:CAS:528:DyaL2sXkslekt7Y%3D 10.1016/0011-2240(87)90023-X
  • Gamero, L.G., Armentano, R.L., Barra, J.G., Simon, A., Levenson, J., Identification of arterial wall dynamics in conscious dogs (2001) Exp. Physiol., 86 (4), pp. 519-528. , 11445831 1:STN:280:DC%2BD38%2FivVWrsQ%3D%3D 10.1113/eph8602172
  • Gournier, J.P., Adham, M., Favre, J.P., Raba, M., Bancel, B., Lepetit, J.C., Barral, X., Cryopreserved arterial homografts: Preliminary study (1993) Ann. Vasc. Surg., 7 (6), pp. 503-511. , 8123452 1:STN:280:ByuC28fpt1M%3D 10.1007/BF02000144
  • Hunt, C.J., Song, Y.C., Bateson, E.A., Pegg, D.E., Fractures in cryopreserved arteries (1994) Cryobiology, 31 (5), pp. 506-515. , 7988160 1:STN:280:ByqD2sbnslA%3D 10.1006/cryo.1994.1061
  • Karlsson, J.O., Toner, M., Long-term storage of tissues by cryopreservation: Critical issues (1996) Biomaterials, 17 (3), pp. 243-256. , 8745321 1:CAS:528:DyaK28XovVSnsQ%3D%3D 10.1016/0142-9612(96)85562-1
  • Langerak, S.E., Groenink, M., der Wall, E.E., Wassenaar, C., Vanbavel, E., van Baal, M.C., Spaan, J.A., Impact of current cryopreservation procedures on mechanical and functional properties of human aortic homografts (2001) Transpl. Int., 14 (4), pp. 248-255. , 11512058 1:STN:280:DC%2BD3MvmslWntg%3D%3D 10.1111/ j.1432-2277.2001.tb00053.x
  • Lehalle, B., Geschier, C., Fieve, G., Stoltz, J.F., Early rupture and degeneration of cryopreserved arterial allografts (1997) J. Vasc. Surg., 25 (4), pp. 751-752. , 9129634 1:STN:280:ByiB2sroslc%3D 10.1016/S0741-5214(97)70305-7
  • Ljung, L., (1999) System Identification - Theory for the User, , 2 Upper Saddle River NJ, Prentice Hall
  • Pascual, G., Jurado, F., Rodriguez, M., Corrales, C., Lopez-Hervas, P., Bellon, J.M., Bujan, J., The use of ischaemic vessels as prostheses or tissue engineering scaffolds after cryopreservation (2002) Eur. J. Vasc. Endovasc. Surg., 24 (1), pp. 23-30. , 12127844 1:STN:280:DC%2BD38zotFyrtg%3D%3D 10.1053/ejvs.2002.1663
  • Pegg, D.E., Wusteman, M.C., Boylan, S., Fractures in cryopreserved elastic arteries (1997) Cryobiology, 34 (2), pp. 183-192. , 9130389 1:STN:280:ByiB2snms1Y%3D 10.1006/cryo.1996.1997
  • Peterson, L.H., Jensen, R.E., Parnell, J., Mechanical properties of arteries in vivo (1960) Circ. Res., 8, pp. 622-639
  • Pontrelli, G., Rossoni, E., Numerical modelling of the pressure wave propagation in the arterial flow (2003) Int. J. Numer. Meth. Fluids, 43, pp. 651-671. , 10.1002/fld.494
  • Pukacki, F., Jankowski, T., Gabriel, M., Oszkinis, G., Krasinski, Z., Zapalski, S., The mechanical properties of fresh and cryopreserved arterial homografts (2000) Eur. J. Vasc. Endovasc. Surg., 20 (1), pp. 21-24. , 10906292 1:STN:280:DC%2BD3cvgtF2gug%3D%3D 10.1053/ejvs.2000.1120
  • Rendal, M.E., Vazquez, M., Rodriguez Cabarcos, M.V., Martinez Santos, R.O., Fernandez Mallo, J., Sanchez Ibanez, R., Segura Iglesias, G., Andion Nunez, C., Functional assessment of cryopreserved human aortas for pharmaceutical research (2004) Cell Tissue Bank, 5 (2), pp. 119-123. , 15241008 10.1023/B:CATB.0000034087.26468.5a
  • Rigol, M., Heras, M., Martinez, A., Zurbano, M.J., Agusti, E., Roig, E., Pomar, J.L., Sanz, G., Changes in the cooling rate and medium improve the vascular function in cryopreserved porcine femoral arteries (2000) J. Vasc. Surg., 31 (5), pp. 1018-1025. , 10805894 1:STN:280:DC%2BD3c3ms1agug%3D%3D 10.1067/mva.2000.103793
  • Seifalian, A.M., Tiwari, A., Hamilton, G., Salacinski, H.J., Improving the clinical patency of prosthetic vascular and coronary bypass grafts: The role of seeding and tissue engineering (2002) Artif. Organs, 26 (4), pp. 307-320. , 11952502 10.1046/j.1525-1594.2002.06841.x
  • Shepherd, J.P., Dawber, R.P., The response of keloid scars to cryosurgery (1982) Plast Reconstr. Surg, 70 (6), pp. 677-682. , 7146149 1:STN:280:BiyD28rntFY%3D
  • Shepherd, J.P., Dawber, R.P., Wound healing and scarring after cryosurgery (1984) Cryobiology, 21 (2), pp. 157-169. , 6713945 1:STN:280:BiuC1c7nslY%3D 10.1016/0011-2240(84)90207-4
  • Tai, N.R., Giudiceandrea, A., Salacinski, H.J., Seifalian, A.M., Hamilton, G., In vivo femoropopliteal arterial wall compliance in subjects with and without lower limb vascular disease (1999) J Vasc Surg, 30 (5), pp. 936-945. , 10550193 1:STN:280:DC%2BD3c%2FhvVeisg%3D%3D 10.1016/S0741-5214(99)70020-0
  • Tai, N.R., Salacinski, H.J., Edwards, A., Hamilton, G., Seifalian, A.M., Compliance properties of conduits used in vascular reconstruction (2000) Br. J. Surg., 87 (11), pp. 1516-1524. , 11091239 1:STN:280:DC%2BD3M%2FltFOitQ%3D%3D 10.1046/ j.1365-2168.2000.01566.x
  • Vischjager, M., Gulik, T.M., Van Marle, J., Van Pfaffendorf, M., Jacobs, M.J., Function of cryopreserved arterial allografts under immunosuppressive protection with cyclosporine (1996) A J. Vasc. Surg., 24 (5), pp. 876-882. , 8918337 1:STN:280:ByiD2sngtFA%3D 10.1016/S0741-5214(96)70026-5
  • Wassenaar, C., Wijsmuller, E.G., Herwerden, L.A., Van Aghai, Z., Tricht, C.L., Van Bos, E., Cracks in cryopreserved aortic allografts and rapid thawing (1995) Ann. Thorac. Surg., 60 (2 SUPPL.), pp. S165-S167. , 7646151 1:STN:280:ByqA2svhtlM%3D 10.1016/0003-4975(95)00264-L
  • Wells, S.M., Langille, B.L., Lee, J.M., Adamson, S.L., Determinants of mechanical properties in the developing ovine thoracic aorta (1999) Am. J. Physiol., 277 (4 PART 2), pp. H1385-H1391. , 10516173 1:CAS:528:DyaK1MXntF2htLc%3D
  • Westerhof, N., Noordergraaf, A., Arterial viscoelasticity: A generalized model. Effect on input impedance and wave travel in the systematic tree (1970) J. Biomech., 3, pp. 357-379. , 5521552 1:STN:280:CS2D38fns1A%3D 10.1016/0021-9290(70)90036-9

Citas:

---------- APA ----------
Bia, D., Pessana, F., Armentano, R., Pérez, H., Graf, S., Zócalo, Y., Saldías, M.,..., Alvarez, I. (2006) . Cryopreservation procedure does not modify human carotid homografts mechanical properties: An isobaric and dynamic analysis. Cell and Tissue Banking, 7(3), 183-194.
http://dx.doi.org/10.1007/s10561-005-0655-0
---------- CHICAGO ----------
Bia, D., Pessana, F., Armentano, R., Pérez, H., Graf, S., Zócalo, Y., et al. "Cryopreservation procedure does not modify human carotid homografts mechanical properties: An isobaric and dynamic analysis" . Cell and Tissue Banking 7, no. 3 (2006) : 183-194.
http://dx.doi.org/10.1007/s10561-005-0655-0
---------- MLA ----------
Bia, D., Pessana, F., Armentano, R., Pérez, H., Graf, S., Zócalo, Y., et al. "Cryopreservation procedure does not modify human carotid homografts mechanical properties: An isobaric and dynamic analysis" . Cell and Tissue Banking, vol. 7, no. 3, 2006, pp. 183-194.
http://dx.doi.org/10.1007/s10561-005-0655-0
---------- VANCOUVER ----------
Bia, D., Pessana, F., Armentano, R., Pérez, H., Graf, S., Zócalo, Y., et al. Cryopreservation procedure does not modify human carotid homografts mechanical properties: An isobaric and dynamic analysis. Cell Tissue Bank. 2006;7(3):183-194.
http://dx.doi.org/10.1007/s10561-005-0655-0