Artículo

Sadowski, M.; Szydlowski, A.; Scholz, M.; Kelly, H.; Marquez, A.; Lepone, A. "Application of solid-state nuclear track detectors for studies of fast ion beams within PF-1000 and other plasma-focus facilities" (1999) Proceedings of the 1998 19th International Conference on Nuclear Tracks in Solids (ICNTSs). 31(1):185-190
Estamos trabajando para incorporar este artículo al repositorio
Consulte el artículo en la página del editor
Consulte la política de Acceso Abierto del editor

Abstract:

The paper presents results of studies of the fast ion emission from two plasma facilities: PF-1000 and PF-II. The measurements were carried out mainly with solid-state nuclear track detectors (SSNTDs). To register ion mass- and energy-spectra, obtained when primary ion beams are deflected by magnetic and electric fields of a Thomson-type spectrometer, the SSNTDs plates were installed inside the analyzer. To measure ion angular distributions the SSNTDs were located within the main discharge chamber, at different angles to the electrode axis. The SSNTDs were also applied to register ion beam images formed within an ion pinhole camera, and to determine a spatial location of the fast ion sources.

Registro:

Documento: Artículo
Título:Application of solid-state nuclear track detectors for studies of fast ion beams within PF-1000 and other plasma-focus facilities
Autor:Sadowski, M.; Szydlowski, A.; Scholz, M.; Kelly, H.; Marquez, A.; Lepone, A.
Ciudad:Exeter; Besancon, France
Filiación:Andrzej Soltan Institute for Nuclear Studies (IPJ), 05-400 Swierk n. Warsaw, Poland
Kaliski Institute of Plasma Physics and Laser Microfusion (IFPiLM), 00-908 Warsaw, Poland
Instituto de Fisica del Plasma (INFIP-CONICET), UBA, 1428 Buenos Aires, Argentina
Palabras clave:Electric fields; Ion beams; Ion sources; Magnetic fields; Particle beam tracking; Plasmas; Solid state devices; Spectrometers; Ion angular distribution; Ion energy spectra; Ion mass spectra; Solid state nuclear track detectors; Particle detectors
Año:1999
Volumen:31
Número:1
Página de inicio:185
Página de fin:190
DOI: http://dx.doi.org/10.1016/S1350-4487(99)00083-9
Título revista:Proceedings of the 1998 19th International Conference on Nuclear Tracks in Solids (ICNTSs)
Título revista abreviado:Radiat. Meas.
ISSN:13504487
CODEN:RMEAE
Registro:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_13504487_v31_n1_p185_Sadowski

Referencias:

  • Bertalot, L., Herold, H., Jager, U., Mozer, A., Oppenlander, T., Sadowski, M., Schmidt, H., Mass and energy analysis and space-resolved measurements of ions from plasma focus devices (1980) Phys. Letters, 79 A, pp. 389-392
  • Czekaj, S., Denus, S., Szydlowski, A., Fast ion emission from plasma focus (1984) Atomkern. Kerntechnik, 44, pp. 189-191
  • Herold, H., Mozer, A., Sadowski, M., Schmidt, H., Design and calibration of a Thomson ion analyzer from plasma focus studies (1981) Rev. Sci. Instrum., 52, pp. 24-26
  • Kelly, H., Lepone, A., Marquez, A., Nitrogen ion spectrum from a low energy plasma focus device (1997) IEEE Trans. on Plasma Science, 25, pp. 455-459
  • Mozer, A., Sadowski, M., Herold, H., Schmidt, H., Experimental studies of fast deuterons, impurity- And admixture-ions emitted from a plasma focus (1982) J. Appl. Phys., 53, pp. 2959-2964
  • Sadowski, M., Ion beams from high-current PF facilities (1996) Proc. BEAMS'96 - 11th Intern. Conf. on High Power Particle Beams, 1, pp. 170-173. , Prague, 1996
  • Sadowski, M., Zebrowski, J., Rydygier, E., Kucinski, J., Ion emission from plasma-focus facilities (1988) Plasma Phys. and Controlled Fusion, 30, pp. 763-769
  • Stygar, W., Gerdin, G., Venneri, F., Mandreakas, J., Particle beams generated by a 6-12.5 kJ dense plasma focus (1982) Nucl Fusion, 22, pp. 1161-1172A4 - Agence de Developpement Economique du Doubs; Region de Franche-Comte; Societe Francaise de Chimie; Universite de Franche-Comt; Ville de Besancon

Citas:

---------- APA ----------
Sadowski, M., Szydlowski, A., Scholz, M., Kelly, H., Marquez, A. & Lepone, A. (1999) . Application of solid-state nuclear track detectors for studies of fast ion beams within PF-1000 and other plasma-focus facilities. Proceedings of the 1998 19th International Conference on Nuclear Tracks in Solids (ICNTSs), 31(1), 185-190.
http://dx.doi.org/10.1016/S1350-4487(99)00083-9
---------- CHICAGO ----------
Sadowski, M., Szydlowski, A., Scholz, M., Kelly, H., Marquez, A., Lepone, A. "Application of solid-state nuclear track detectors for studies of fast ion beams within PF-1000 and other plasma-focus facilities" . Proceedings of the 1998 19th International Conference on Nuclear Tracks in Solids (ICNTSs) 31, no. 1 (1999) : 185-190.
http://dx.doi.org/10.1016/S1350-4487(99)00083-9
---------- MLA ----------
Sadowski, M., Szydlowski, A., Scholz, M., Kelly, H., Marquez, A., Lepone, A. "Application of solid-state nuclear track detectors for studies of fast ion beams within PF-1000 and other plasma-focus facilities" . Proceedings of the 1998 19th International Conference on Nuclear Tracks in Solids (ICNTSs), vol. 31, no. 1, 1999, pp. 185-190.
http://dx.doi.org/10.1016/S1350-4487(99)00083-9
---------- VANCOUVER ----------
Sadowski, M., Szydlowski, A., Scholz, M., Kelly, H., Marquez, A., Lepone, A. Application of solid-state nuclear track detectors for studies of fast ion beams within PF-1000 and other plasma-focus facilities. Radiat. Meas. 1999;31(1):185-190.
http://dx.doi.org/10.1016/S1350-4487(99)00083-9