Registro:
Documento: |
Artículo
|
Título: | A computational dosimetry tool for the study of tumor doses and skin toxicities in BNCT |
Autor: | Gossio, S.; Carando, D.G.; González, S.J. |
Filiación: | FCEyN, UBA, Pab. II Ciudad Universitaria, (1428) Cdad. de Buenos Aires, Argentina Dpto. de Matemática, UBA, Pab. I Ciudad Universitaria, (1428) Cdad. de Buenos Aires, Argentina CONICET, Avda. Rivadavia 1917, (1033) Cdad. Buenos Aires, Argentina Comisión Nacional de Energía Atómica, Av. del Libertador 8250, (1429) Cdad. de Buenos Aires, Argentina
|
Palabras clave: | Computational dosimetry; Melanoma; Treatment planning system; Computational dosimetry; Computational tools; Dose distributions; Dose-volume histograms; Melanoma; Normal tissue; Skin dose; Skin toxicity; Treatment planning system; Tumor dose; Visual representations; Volumes of interests; Dosimeters; Dosimetry; MATLAB; Skin; Tumors; article; computer analysis; computer assisted tomography; computer interface; computer program; dosimetry; histogram; human; image analysis; melanoma; neutron capture therapy; priority journal; radiation dose; radiation dose distribution; skin toxicity; three dimensional imaging; treatment planning; tumor localization; Argentina; Boron Neutron Capture Therapy; Humans; Imaging, Three-Dimensional; Melanoma; Radiation Injuries; Radiotherapy Planning, Computer-Assisted; Skin; Skin Neoplasms; Software |
Año: | 2009
|
Volumen: | 67
|
Número: | 7-8 SUPPL
|
Página de inicio: | S145
|
Página de fin: | S148
|
DOI: |
http://dx.doi.org/10.1016/j.apradiso.2009.03.036 |
Título revista: | Applied Radiation and Isotopes
|
Título revista abreviado: | Appl. Radiat. Isot.
|
ISSN: | 09698043
|
CODEN: | ARISE
|
Registro: | https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_09698043_v67_n7-8SUPPL_pS145_Gossio |
Referencias:
- González, S.J., Santa Cruz, G.A., Kiger III, W.S., Goorley, J.T., Palmer, M.R., Busse, P.M., Zamenhof, R.G., NCTPlan, the New PC version of MacNCTPlan: Improvements and verification of a BNCT treatment planning system (2002) Proceedings of the Tenth International Congress on Neutron Capture Therapy, pp. 557-561. , Sauerwein, W, Moss, R, Wittig, A, Eds, Monduzzi Editore, Bologna, pp
- González, S.J., Bonomi, M.R., Santa Cruz, G.A., Blaumann, H.R., Calzetta Larrieu, O.A., Menéndez, P., Jiménez Rebagliati, R., Roth, B.M.C., First BNCT treatment of a skin melanoma in Argentina: dosimetric analysis and clinical outcome (2004) Appl. Radiat. Isotopes, 61, pp. 1101-1105
- González, S.J., Carando, D.G., Santa Cruz, G.A., Zamenhof, R.G., Voxel model in BNCT treatment planning: performance analysis and improvements (2005) Phys. Med. Biol., 50, pp. 441-458
- González, S.J., Casal, M., Pereira, M.D., Santa Cruz, G.A., Carando, D.G., Blaumann, H., Bonomi, M., Calzetta Larrieu, O., Feld, D., Fernández, C., Gossio, S., Jiménez Rebagliatti, R., Kessler, J., Longhino, J., Menéndez, P., Nievas, S., Roth, B.M.C., Liberman, S.J., 2009. Tumor control and normal tissue complications in BNCT treatment of nodular melanoma: A search for predictive quantities. Appl. Radiat. Isotopes, this issue, doi:10.1016/j.apradiso.2009.03.038; Menéndez, P.R., Roth, B.M.C., González, S.J., Santa Cruz, G.A., Blaumann, H., Calzetta Larrieu, O.A., Feld, D.B., Casal, M.R., Jimenez Rebagliati, R., Nievas, S.I., Longhino, J., Pereira, M.D., Fernandez, C., Kessler, J., Liberman, S.J., 2009. BNCT for skin melanoma in extremities: Updated Argentine clinical results. Appl. Radiat. Isotopes, this issue, doi:10.1016/j.apradiso.2009.03.020; Santa Cruz, G.A., Bertotti, J., Marín, J., González, S.J., Gossio, S., Alvarez, D., Roth, B.M.C., Menéndez, P., Pereira, M.D., Albero, M., Cubau, L., Orellano, P., Liberman, S.J., 2009. Dynamic infrared imaging of cutaneous melanoma and normal skin in patients treated by BNCT. Appl. Radiat. Isotopes, this issue, doi:10.1016/j.apradiso.2009.03.093
Citas:
---------- APA ----------
Gossio, S., Carando, D.G. & González, S.J.
(2009)
. A computational dosimetry tool for the study of tumor doses and skin toxicities in BNCT. Applied Radiation and Isotopes, 67(7-8 SUPPL), S145-S148.
http://dx.doi.org/10.1016/j.apradiso.2009.03.036---------- CHICAGO ----------
Gossio, S., Carando, D.G., González, S.J.
"A computational dosimetry tool for the study of tumor doses and skin toxicities in BNCT"
. Applied Radiation and Isotopes 67, no. 7-8 SUPPL
(2009) : S145-S148.
http://dx.doi.org/10.1016/j.apradiso.2009.03.036---------- MLA ----------
Gossio, S., Carando, D.G., González, S.J.
"A computational dosimetry tool for the study of tumor doses and skin toxicities in BNCT"
. Applied Radiation and Isotopes, vol. 67, no. 7-8 SUPPL, 2009, pp. S145-S148.
http://dx.doi.org/10.1016/j.apradiso.2009.03.036---------- VANCOUVER ----------
Gossio, S., Carando, D.G., González, S.J. A computational dosimetry tool for the study of tumor doses and skin toxicities in BNCT. Appl. Radiat. Isot. 2009;67(7-8 SUPPL):S145-S148.
http://dx.doi.org/10.1016/j.apradiso.2009.03.036