Abstract:
A bimetallic porphyrin film was studied as electrode modifier with catalytic activity for molecular oxygen reduction and hydrogen peroxide reduction. Molecular oxygen reduction is catalyzed by both polyFePPIX or polyCuPPIX. Peroxidase activity at-200 mV versus Ag/AgCl is only performed by polyFePPIX in absence of oxidative agents, and the deposit polyCuPPIX is required to perform peroxidase activity in the presence of oxygen. Copper substitution by other metals in the porphyrin was not effective. It has been found that metalloporphyrin immobilization order acquire particular relevance. However, the mass of porphyrin deposit is always 1.5-1.6 μg of polyFePPIX and 7.3-9.1 μg of polyCuPPIX, indicating that polymer growth rate is not affected by immobilization order. polyCuPPIX deposited on polyFePPIX preserves catalytic properties over a wide pH range, and acts as a molecular sieve. The use of this bimetallic electrode in a first-generation oxidase biosensors is discussed. © 2003 Elsevier B.V. All rights reserved.
Registro:
Documento: |
Artículo
|
Título: | New bimetallic porphyrin film: An electrocatalytic transducer for hydrogen peroxide reduction, applicable to first-generation oxidase-based biosensors |
Autor: | Vago, J.M.; Dall'Orto, V.C.; Forzani, E.; Hurst, J.; Rezzano, I.N. |
Filiación: | Depto. de Química Analtica, Fac. de Farmacia/Bioquímica, Universidad de Buenos Aires, Junín 956, CP 1113 Buenos Aires, Argentina INQUIMAE, Depto. de Quim. Inorg., Ciudad Universitaria, Pabellón 2, CP 1428 Buenos Aires, Argentina
|
Palabras clave: | Bimetallic film; Catalyst; Electropolymerization; Hydrogen peroxide; Catalyst activity; Electropolymerization; Enzyme sensors; Hydrogen peroxide; Oxygen; Porphyrins; Reduction; Transducers; Electrocatalytic transducers; Bimetals |
Año: | 2003
|
Volumen: | 96
|
Número: | 1-2
|
Página de inicio: | 407
|
Página de fin: | 412
|
DOI: |
http://dx.doi.org/10.1016/S0925-4005(03)00575-6 |
Título revista: | Sensors and Actuators, B: Chemical
|
Título revista abreviado: | Sens Actuators, B Chem
|
ISSN: | 09254005
|
CODEN: | SABCE
|
Registro: | https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_09254005_v96_n1-2_p407_Vago |
Referencias:
- Turner, A.P.F., Karube, I., Wilson, G.S., (1987) Biosensors, Fundamentals and Applications, , Oxford University Press, New York
- Darder, M., Takada, K., Pariente, F., Lorenzo, E., Abruña, H.D., Dithiobissuccinimidyl propionate as an anchor for assembling peroxidases at electrodes surfaces and its application in a H2O2 biosensor (1999) Anal. Chem., 71 (24), p. 5530
- Malitesta, C., Palmisano, F., Torsi, L., Zambonin, P., Glucose fast-response amperometric sensor based on glucose oxidase immobilized in an electropolymerized poly(o-phenylenediamine) film (1990) Anal. Chem., 62, p. 2735
- Karyakin, A., Gitelmacher, O., Karyakina, E., Prussian Blue-based first-generation biosensor. A sensitive amperometric electrode for glucose (1995) Anal. Chem., 67 (14), p. 2419
- Chi, Q., Dong, S., Amperometric biosensors based on the immobilization of oxidases in a Prussian blue film by electrochemical codeposition (1995) Anal. Chim. Acta, 310, p. 429
- Itaya, K., Shoji, N., Uchida, I., Catalysis of the reduction of molecular oxygen to water at Prussian blue modified electrodes (1984) J. Am. Chem. Soc., 106 (12), p. 3423
- Wang, J., Zhang, X., Prakash, M., Glucose microsensors based on carbon paste enzyme electrodes modified with cupric hexacyanoferrate (1999) Anal. Chim. Acta, 395 (1), p. 11
- Ferguson-Miller, S., Babcock, G., Heme/copper terminal oxidases (1996) Chem. Rev., 96, p. 2889
- Wikstrom, M., Morgan, J.E., The dioxygen cycle (1992) J. Biol. Chem., 267 (15), p. 10266
- Fu, L., Herrmann, P., Zhang, X., Collman, J.P., A functional model related to cytochrome c oxidase and its electrocatalytic four-electron reduction of O2 (1997) Science, 275, p. 949
- Campo Dall'Orto, V., Danilowicz, C., Sobral, S., Lo Balbo, A., Rezzano, I., Liquid chromatography/electrochemical detection of phenols at a poly [Ni-(protoporphyrin IX)] chemically modified electrode (1996) Anal. Chim. Acta, 336 (1-3), p. 195
- Campo Dall'Orto, V., Danilowicz, C., Hurst, J., Lo Balbo, A., Rezzano, I., Studies of the interaction between metalloporphyrin films and phenols in a preconcentration type sensor (1998) Electroanalysis, 10 (2), p. 127
- Luiz de Mattos, I., Lukachova, L., Gorton, L., Laurell, T., Karyakin, A., Evaluation of glucose biosensors based on Prussian Blue and lyophilised, chrystalline and cross-linked glucose oxidases (CLEC) (2001) Talanta, 54, p. 963
- Campo Dall'Orto, V., Danilowicz, C., Hurst, J., Lo Balbo, A., Rezzano, I., Studies of the interaction between metalloporphyrin films and phenols in a preconcentration type sensor (1998) Electroanalysis, 10 (2), p. 127
- Calvo, E.J., Danilowicz, C., Etchenique, R., Measurement of viscoelastic changes at electrodes modified with redox hydrogels with a quartz crystal device (1995) J. Chem. Soc., Faraday Trans., p. 4083
- Vago, M., Campodall'Orto, V., Rezzano, I., Forzani, E., Calvo, E.J., Metallo-porphyrin Electropolymerization: Electrochemical Quartz Crystal Microgravimetric Studies, , manuscript in preparation
Citas:
---------- APA ----------
Vago, J.M., Dall'Orto, V.C., Forzani, E., Hurst, J. & Rezzano, I.N.
(2003)
. New bimetallic porphyrin film: An electrocatalytic transducer for hydrogen peroxide reduction, applicable to first-generation oxidase-based biosensors. Sensors and Actuators, B: Chemical, 96(1-2), 407-412.
http://dx.doi.org/10.1016/S0925-4005(03)00575-6---------- CHICAGO ----------
Vago, J.M., Dall'Orto, V.C., Forzani, E., Hurst, J., Rezzano, I.N.
"New bimetallic porphyrin film: An electrocatalytic transducer for hydrogen peroxide reduction, applicable to first-generation oxidase-based biosensors"
. Sensors and Actuators, B: Chemical 96, no. 1-2
(2003) : 407-412.
http://dx.doi.org/10.1016/S0925-4005(03)00575-6---------- MLA ----------
Vago, J.M., Dall'Orto, V.C., Forzani, E., Hurst, J., Rezzano, I.N.
"New bimetallic porphyrin film: An electrocatalytic transducer for hydrogen peroxide reduction, applicable to first-generation oxidase-based biosensors"
. Sensors and Actuators, B: Chemical, vol. 96, no. 1-2, 2003, pp. 407-412.
http://dx.doi.org/10.1016/S0925-4005(03)00575-6---------- VANCOUVER ----------
Vago, J.M., Dall'Orto, V.C., Forzani, E., Hurst, J., Rezzano, I.N. New bimetallic porphyrin film: An electrocatalytic transducer for hydrogen peroxide reduction, applicable to first-generation oxidase-based biosensors. Sens Actuators, B Chem. 2003;96(1-2):407-412.
http://dx.doi.org/10.1016/S0925-4005(03)00575-6