Abstract:
Measurements with magnetic probes performed in the initial phase of a plasma focus device (30 kV, 10.5 μF) in the pressure range 0.5-5 mbar deuterium are presented, and an interpretation of the obtained signals is given, which includes a procedure for disentangling the effect of variations in the discharge current from the signals. Thick current sheaths, essentially filling all the space between the electrodes, are shown to form at all pressures, travelling radially outwards at constant speeds of between 2.5 and 3.4 cm μs-1. Experimental confirmation of a theoretical prediction of distortions in the registered signals due to current exclusions by the probe's body is given, and evidence confirming the 'inverse skin' effect is presented. © 1997 IOP Publishing Ltd.
Registro:
Documento: |
Artículo
|
Título: | Magnetic probe measurements of the initial phase in a plasma focus device |
Autor: | Bruzzone, H.; Grondona, D. |
Filiación: | INFIP, Universidad de Buenos Aires - CONICET, Ciudad Universitaria, 1428 Buenos Aires, Argentina Carrera del Investigador, CONICET, Argentina CONICET, Argentina
|
Palabras clave: | Deuterium; Electric current measurement; Electric discharges; Plasma sheaths; Skin effect; Inverse skin effect; Plasma focus devices; Plasma devices |
Año: | 1997
|
Volumen: | 39
|
Número: | 9
|
Página de inicio: | 1315
|
Página de fin: | 1326
|
DOI: |
http://dx.doi.org/10.1088/0741-3335/39/9/004 |
Título revista: | Plasma Physics and Controlled Fusion
|
Título revista abreviado: | Plasma Phys Controlled Fusion
|
ISSN: | 07413335
|
CODEN: | PLPHB
|
Registro: | https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_07413335_v39_n9_p1315_Bruzzone |
Referencias:
- Bostick, W.H., Prior, W., Farber, E., (1965) Phys. Fluids, 8, p. 745
- Bruzzone, H., Kelly, H., Moreno, C., (1990) IEEE Trans. Plasma Sci., 18, pp. 689-694
- Bruzzone, H., Moreno, C., Kelly, H., (1991) Meas. Sci. Technol., 2, p. 1195
- Bruzzone, H., Vieytes, R., (1993) Plasma Phys. Control. Fusion, 35, pp. 1745-1754
- Bruzzone, H., Grondona, D., Kelly, H., Marquez, A., Moreno, C., Vieytes, R., (1994) 3rd Int. Conf. on Dense Z-pinches, 299, pp. 281-287. , ed M Haines and A Knight (New York: AIP)
- Decker, G., Kiess, W., Pross, G., (1983) Phys. Fluids, 26, p. 571
- Eltgroth, P., (1982) Phys. Fluids, 25, p. 12
- Filippov, N.V., Filippova, T.I., Vinogradov, V.P., (1962) Nucl. Fusion (Suppl), 2, p. 577
- Gourlan, C., Kroegler, H., Maissonier, C.H., Rager, J.P., Robouch, B., Bertalot, L., Gentilini, A., Nucl. Fusion (Suppl), 2, p. 123
- Haines, M.G., (1959) Proc. Phys. Soc., London, 74, p. 576
- Krompholz, H., Neff, W., Rühl, F., Schönbach, K., Herziger, G., (1980) Phys. Lett., 77 A, p. 246
- Mather, J.W., (1965) Phys. Fluids, 8, p. 366
- Mather, J.W., (1971) Methods of Experimental Physics, 9 B, p. 199
- Oppenlander, T., (1978) CNEN - Centro di Frascati, Report 78.6
- Sadowski, M., (1991) Proc. ICPIG XX (Pisa) Invited Papers, p. 274. , ed V Palleschi, D P Singh and M Vaselli (Pisa: Istituto di Fisica Atomica e Moleculare)
Citas:
---------- APA ----------
Bruzzone, H. & Grondona, D.
(1997)
. Magnetic probe measurements of the initial phase in a plasma focus device. Plasma Physics and Controlled Fusion, 39(9), 1315-1326.
http://dx.doi.org/10.1088/0741-3335/39/9/004---------- CHICAGO ----------
Bruzzone, H., Grondona, D.
"Magnetic probe measurements of the initial phase in a plasma focus device"
. Plasma Physics and Controlled Fusion 39, no. 9
(1997) : 1315-1326.
http://dx.doi.org/10.1088/0741-3335/39/9/004---------- MLA ----------
Bruzzone, H., Grondona, D.
"Magnetic probe measurements of the initial phase in a plasma focus device"
. Plasma Physics and Controlled Fusion, vol. 39, no. 9, 1997, pp. 1315-1326.
http://dx.doi.org/10.1088/0741-3335/39/9/004---------- VANCOUVER ----------
Bruzzone, H., Grondona, D. Magnetic probe measurements of the initial phase in a plasma focus device. Plasma Phys Controlled Fusion. 1997;39(9):1315-1326.