Abstract:

A method to accurately determine and quantify manganese, molybdenum and zinc using Optical Emission Spectroscopy-Inductively Coupled Plasma by optical emission spectrometer was optimized and validated. Selectivity/specificity, linearity, repeatability, intermediate precision and bias using reference materials and certified matrix reference material, respectively, were determined. Selected wavelengths (nm) Zn 213.857; Mn 257.610 and Mo 202.031 made it possible to discriminate spectral interferences. Linearity was proved by ad hoc statistical evaluations. Intermediate precision ranged between 5 and 11% and bias was never greater than 12%. Quantification limits (mg/L) were: Mn: 5; Zn: 10 y Mo: 10. Uncertainties associated to analytical determinations ranged between 10% and 16%. The validation of the proposed method demonstrated that it is selective, it provides adequate uncertainties and it is useful to quantify quickly and accurately the studied trace metals in matrices that can be taken intoaqueous solution with prior digestion in acid medium.

Registro:

Documento: Artículo
Título:Validation of the determination of manganese, molibdenum and zinc using inductively coupled plasma
Autor:Farías, S.S.; Menéndez, A.M.; Pontiggia, R.M.; Servant, R.E.; Cortez, I.; De Portela, M.L.P.M.
Filiación:Gerencia de Química, Centro Atómico Constituyentes, Comisión Nacional de Energía Atómica, Av. General Paz 1499. San Martín, Provincia de Buenos Aires, Argentina
Facultad de Ciencias Exactas y Naturales y Ciencias de la Salud, Carrera de Farmacia, Universidad de Belgrano, Villanueva 1324, Ciudad Autónoma de Buenos Aires, Argentina
Universidad de Belgrano, Villanueva 1324, Ciudad Autónoma de Buenos Aires, Argentina
Benito Roggio Ambiental SA, Salguero 3800, Ciudad Autónoma de Buenos Aires, Argentina
Universidad de Buenos Aires, Facultad de Farmacia y Bioquímica, Departamento de Sanidad, Nutricion, Bromatologia y Toxicologia, Catedra de Nutricion, Buenos Aires, Argentina
Palabras clave:Inductively Coupled Plasma; Manganese; Molybdenum; Validation; Zinc
Año:2016
Volumen:50
Número:4
Página de inicio:635
Página de fin:642
Título revista:Acta Bioquimica Clinica Latinoamericana
Título revista abreviado:Acta Bioquim. Clin. Latinoam.
ISSN:03252957
CODEN:ABCLD
Registro:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03252957_v50_n4_p635_Farias

Referencias:

  • (1996) Trace Elements in Human Nutrition and Health, , WHO/FAO/IAEA. World Health Organization. Geneva
  • Mertz, W., Review of the scientific basis for establishing the essentiality of trace elements (1998) Biol Trace Element Res, 66, pp. 185-191
  • Sandoval, S., (2010) Validación de Métodos y Determinación de la Incertidumbre de la Medición: Aspectos Generales Sobre la Validación de Métodos, , Guía Técnica N0. 1. Sección Metrología Ambiental y de Alimentos. Departamento de Salud Ambiental. Santiago de Chile
  • Strathmann, F.G., Hoofnagle, A.N., Current and future applications of mass spectrometry to the clinical laboratory (2011) Am J Clin Pathol, 136, pp. 609-616
  • (2001) Dietary Reference Intakes for Vitamin A, Vitamin K, Arsenic, Boron, Chromium, Copper, Iodine, Iron, Molybdenum, Nickel, Silicon, Vanadium and Zinc, , Standing Committee on the Scientific Evaluation of Dietary References Intakes, Food and Nutrition Board & Institute of Medicine. National Academy of Sciences. Washington D.C
  • Horwitz, W., Evaluation of analytical methods used for regulation of food and drugs (1982) Anal Chem, 54 (1), pp. 67A-76A
  • Towards a harmonized TDS approach: A guidance document (2011) EFSA J, 9 (11), p. 2450. , EFSA (European Food Safety Authority)/FAO/OMS
  • (2014) A Laboratory Guide to Method Validation and Related Topics, , The Fitness for Purpose of Analytical Methods. EURACHEM Guide. Editor: H. Holcombe. Teddington: LGC
  • Requisitos Generales para la Competencia de Los Laboratorios de Ensayo y de Calibración, , http://www.chromu.com/calidad/DOCS/norma%20iso%2017025/iso_17025.pdf, Norma IRAM 301:2005/ISO/IEC 17025:2005. 4ta. Edición, Buenos Aires, Argentina. [citado 2005 mayo 9]. Consultado 25 de abril de 2016
  • (2014) Criterios Generales para la Acreditación de Laboratorios de Ensayo y Calibración Según Norma, , UNE-EN ISO/IEC 17025:2005 CGA-ENAC-LEC Rev. 6 Octubre
  • Butner, J., Borth, R., Boutwell, J.H., Broughton, P.M.G., Approved recommendation on quality control in clinical chemistry. Part 2. Assessment of analytical methods for routine use (1979) Clin Chim Acta, 98, pp. F145-F162
  • Magnusson, B., Näykk, T., Hovind, H., Krysell, M., Handbook for calculation of measurement uncertainty in environmental laboratories. 3rd edition (2012) Finland: Nordtest, 52 (2012), p. 52

Citas:

---------- APA ----------
Farías, S.S., Menéndez, A.M., Pontiggia, R.M., Servant, R.E., Cortez, I. & De Portela, M.L.P.M. (2016) . Validation of the determination of manganese, molibdenum and zinc using inductively coupled plasma . Acta Bioquimica Clinica Latinoamericana, 50(4), 635-642.
Recuperado de https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03252957_v50_n4_p635_Farias [ ]
---------- CHICAGO ----------
Farías, S.S., Menéndez, A.M., Pontiggia, R.M., Servant, R.E., Cortez, I., De Portela, M.L.P.M. "Validation of the determination of manganese, molibdenum and zinc using inductively coupled plasma " . Acta Bioquimica Clinica Latinoamericana 50, no. 4 (2016) : 635-642.
Recuperado de https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03252957_v50_n4_p635_Farias [ ]
---------- MLA ----------
Farías, S.S., Menéndez, A.M., Pontiggia, R.M., Servant, R.E., Cortez, I., De Portela, M.L.P.M. "Validation of the determination of manganese, molibdenum and zinc using inductively coupled plasma " . Acta Bioquimica Clinica Latinoamericana, vol. 50, no. 4, 2016, pp. 635-642.
Recuperado de https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03252957_v50_n4_p635_Farias [ ]
---------- VANCOUVER ----------
Farías, S.S., Menéndez, A.M., Pontiggia, R.M., Servant, R.E., Cortez, I., De Portela, M.L.P.M. Validation of the determination of manganese, molibdenum and zinc using inductively coupled plasma . Acta Bioquim. Clin. Latinoam. 2016;50(4):635-642.
Available from: https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03252957_v50_n4_p635_Farias [ ]