Artículo

Vargas, L.J.; Vila, A.; Lanza, A.; Bonvehi, P.; Nazar, J.; Mikietuk, A.; Labat, R.; Smayevsky, J. "Utility of VITEK system for bacterial identification and antimicrobial susceptibility testing " (2005) Acta Bioquimica Clinica Latinoamericana. 39(1):19-25
Estamos trabajando para incorporar este artículo al repositorio
Consulte la política de Acceso Abierto del editor

Abstract:

The identification (ID) and antimicrobial susceptibility testing (AST) of clinically significant bacteria provide essential information for the effective management of patients with infectious diseases. In the present study 212 isolates from hospitalized patients were tested by VITEK and traditional overnight methods in order to determine the accuracy of automated VITEK for ID and AST. The type and number of isolates tested were: 94 Enterobacteriaceae isolates, 67 non-glucose-fermenting gram-negative-rods, 29 coagulase-negative- staphylococci, 22 Enterococcus spp. and 21 S. aureus (for AST only). The 98.1 % of the isolates was correctly identified at genera and species level and the concordance in AST was 99.5%. The turnaround time (TAT) for the reporting AST results was 7.8 h using VITEK and 24 h for Kirby Bauer. Change in the antimicrobial therapy using VITEK susceptibility results could have been made 16 hs sooner than using conventional methods, in 46% of the patients evaluated. The conclusion is that the inclusion of rapid methods for bacterial identification and susceptibility tests might improve the management of infected patients.

Registro:

Documento: Artículo
Título:Utility of VITEK system for bacterial identification and antimicrobial susceptibility testing
Autor:Vargas, L.J.; Vila, A.; Lanza, A.; Bonvehi, P.; Nazar, J.; Mikietuk, A.; Labat, R.; Smayevsky, J.
Filiación:Laboratorio de Microbiología, Argentina
C.E.M.I.C. (Ctro. de Educación Médica e Invest. Clínicas Norberto Quirno), Sección de Infectología, Galván 4102, 1431 Ciudad de Buenos Aires, Argentina
Laboratorio BioMérieux, Av. Congreso 1745, 1428 Ciudad de Buenos Aires, Argentina
Olleros 3207 PB, 1426 Ciudad de Buenos Aires, Argentina
Palabras clave:Antimicrobial susceptibility; Identification; VITEK; amikacin; ampicillin; cefepime; cefotetan; ciprofloxacin; gentamicin; piperacillin; streptomycin; sultamicillin; vancomycin; accuracy; antibiotic sensitivity; antimicrobial therapy; article; automation; bacterium identification; bacterium isolate; Enterobacteriaceae; Enterococcus; Gram negative bacterium; hospitalization; nonhuman; Staphylococcus; Staphylococcus aureus; Enterobacteriaceae; Enterococcus; Negibacteria; staphylococci; Staphylococcus; Staphylococcus aureus
Año:2005
Volumen:39
Número:1
Página de inicio:19
Página de fin:25
Título revista:Acta Bioquimica Clinica Latinoamericana
Título revista abreviado:Acta Bioquim. Clin. Latinoam.
ISSN:03252957
CODEN:ABCLD
CAS:amikacin, 37517-28-5, 39831-55-5; ampicillin, 69-52-3, 69-53-4, 7177-48-2, 74083-13-9, 94586-58-0; cefepime, 88040-23-7; cefotetan, 69712-56-7, 74356-00-6; ciprofloxacin, 85721-33-1; gentamicin, 1392-48-9, 1403-66-3, 1405-41-0; piperacillin, 59703-84-3, 61477-96-1; streptomycin, 57-92-1; sultamicillin, 76497-13-7; vancomycin, 1404-90-6, 1404-93-9
Registro:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03252957_v39_n1_p19_Vargas

Referencias:

  • Barenfanger, J., Drake, C., Kacich, G., Clinical and financial beneficts of rapid bacterial identification and antimicrobial susceptibility testing (1999) J Clin Microbiol, 37, pp. 1415-1418
  • Doern, G.V., Vautour, R., Gaudet, M., Levy, B., Clinical impact of rapid in vitro susceptibility testing and bacterial identification (1994) J Clin Microbiol, 32, pp. 1757-1762
  • Berke, J., Tierno, P., Comparison of efficacy and cost-effectiveness of BIOMIC VIDEO and VITEK antimicrobial susceptibility test systems for use in the clinical microbiology laboratory (1996) J Clin Microbiol, 34, pp. 1980-1984
  • Sung, L., Yang, D.J., Hung, C.C., Tsung Ho, H., Evaluation of SCAN-W/A and the VITEK GNI automicrobic system for identification of non-glucose fermenting gram-negative bacilli (2000) J Clin Microbiol, 38, pp. 1127-1130
  • O'Hara, C., Westbrook, G., Miller, M., Evaluation of VITEC GNI+ and Becton Dickinson Microbiology Systems Crystal E/NF Identification Systems for Identification of members of the family Enterobacteriaceae and other gram-negative, glucose-fermenting and non-glucose-fermenting bacilli (1997) J Clin Microbiol, 35, pp. 3269-3273
  • Robinson, A., McCarter, Y.S., Tetreault, J., Comparison of Crystal Enteric/Nonfermenter System, API 20E System, and VITEK Automicrobic system for identification of gram-negative bacilli (1995) J Clin Microbiol, 33, pp. 364-370
  • (2000) Methods for Dilution Antimicrobial Susceptibility Tests for Bacteria That Grow Aerobically. 4 th Ed., , Approved standard M7-A 4. National Committee for Clinical Laboratory Standards, Villanova, Pa
  • (2000) Performance Standards for Antimicrobial Disk Susceptibility Tests, 6 th Ed., , Approved standard M2-A6. National Committee for Clinical Laboratory Standards, Villanova, Pa
  • Murray, P.R., Baron, E.J., Pfaller, M.A., Tenover, F.C., Yolken, R.H., (1999) Manual of Clinical Microbiology. 7 th Ed., , Eds, Ellen Jo Barm, Michael A. Pfaller, Fred C. Tenover, Robert H. Yolken. Washington DC. American Society for Microbiology
  • Bantar, C.E., Micucci, M., Fernández Canigia, L., Smayevsky, J., Bianchini, H.M., Synergy characterization for Enterococcus faecal is strains displaying moderately high-level gentamicin and streptomycin resistance (1993) J Clin Microbiol, 31 (7), pp. 1921-1923
  • Paz, J., (2002) Manual de Bioestadística, , Buenos Aires: Ed. CEMIC
  • (1996) GNI+ Technical Bulletin, , bioMerieux WITEK Inc., Hazelwood, Mo
  • Bourbeau, P., Heite, B., Comparison of VITEK GNI and GNI+ Cards for identification of gram-negative bacteria (1998) J Clin Microbiol, 36, pp. 2775-2777
  • Doern, G.V., Brueggemann, A.B., Perla, R., Halkias, D., Jones, R.N., Saubolle, M.A., Multicenter laboratory evaluation of the bioMerieux VITEK antimicrobial susceptibility testing system with 11 antimicrobial agents versus members of the family Enterobacteriaceae and Pseudomonas aeruginosa (1997) J Clin Microbiol, 35, pp. 2115-2119
  • Sanders, C., Peyret, M., Moland, E.S., Schubert, C., Thomson, K.S., Boeufgras, J.M., Ability of the VITEK 2 advanced expert system to identify β-lactam phenotypes in isolates of Enterobacteriaceae and Pseudomonas aeruginosa (2000) J Clin Microbiol, 38, pp. 570-574
  • Steward, C.D., Stocker, S.A., Swenson, J.M., O'Hara, C.M., Edwards, R., Gaynes, R.P., Comparison of agar dilution, disk diffusion, microscan, and VITEK antimicrobial susceptibility testing methods to broth microdilution for detection of fluorquinolone-resistant isolates of the family Enterobacteriaceae (1999) J Clin Microbiol, 37, pp. 544-547
  • Frebourg, N.B., Nouet, D., Lemée, L., Martin, E., Lemeland, J.F., Comparison of ATB Staph, Rapid ATB Staph, VITEK, and E-Test methods for detection of oxacillin heteroresistance in staphylococci possessing mec A (1998) J Clin Microbiol, 36, pp. 52-57
  • Hussain, Z., Stoakes, L., Lanningan, R., Longo, S., Nancekivell, B., Evaluation of screening and commercial methods for detection of methicillin resistance in coagulase-negative staphylococci (1998) J Clin Microbiol, 36, pp. 273-274
  • Marshall, S.A., Pfaller, M.A., Jones, R.N., Ability of the modified VITEK card to detect coagulase-negative staphylococci with meca and oxacillin-resistant phenotypes (1999) J Clin Microbiol, 37, pp. 2122-2123
  • Endtz, H.P., Van Den Braak, N., Van Belkum, A., Goessens, W.H., Kreft, D., Stroebel, A.B., Comparison of eight methods to detect vancomycin resistance in enterococci (1998) J Clin Microbiol, 36, pp. 592-594
  • Jett, B., Free, L., Sahm, D.F., Factors influencing the VITEK gram-positive susceptibility system's detection of vanb-encoded vancomycin resistance among enterococci (1996) J Clin Microbiol, 34, pp. 701-706
  • Kohner, P.C., Patel, R., Uhl, J.R., Garin, K.M., Hopkins, M.K., Wegener, L.T., Comparison of agar dilution, broth microdilution, e-test. Disk diffusion, and automated VITEK methods for testing susceptibilities of Enterococcus spp to Vancomycin (1997) J Clin Microbiol, 35, pp. 3258-3263
  • Shetty, N., Hill, G., Ridgway, The VITEK analyser for routine bacterial identification and susceptibility testing: Protocols, problems and pitfalls (1998) J Clin Pathol, 51, pp. 316-323

Citas:

---------- APA ----------
Vargas, L.J., Vila, A., Lanza, A., Bonvehi, P., Nazar, J., Mikietuk, A., Labat, R.,..., Smayevsky, J. (2005) . Utility of VITEK system for bacterial identification and antimicrobial susceptibility testing . Acta Bioquimica Clinica Latinoamericana, 39(1), 19-25.
Recuperado de https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03252957_v39_n1_p19_Vargas [ ]
---------- CHICAGO ----------
Vargas, L.J., Vila, A., Lanza, A., Bonvehi, P., Nazar, J., Mikietuk, A., et al. "Utility of VITEK system for bacterial identification and antimicrobial susceptibility testing " . Acta Bioquimica Clinica Latinoamericana 39, no. 1 (2005) : 19-25.
Recuperado de https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03252957_v39_n1_p19_Vargas [ ]
---------- MLA ----------
Vargas, L.J., Vila, A., Lanza, A., Bonvehi, P., Nazar, J., Mikietuk, A., et al. "Utility of VITEK system for bacterial identification and antimicrobial susceptibility testing " . Acta Bioquimica Clinica Latinoamericana, vol. 39, no. 1, 2005, pp. 19-25.
Recuperado de https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03252957_v39_n1_p19_Vargas [ ]
---------- VANCOUVER ----------
Vargas, L.J., Vila, A., Lanza, A., Bonvehi, P., Nazar, J., Mikietuk, A., et al. Utility of VITEK system for bacterial identification and antimicrobial susceptibility testing . Acta Bioquim. Clin. Latinoam. 2005;39(1):19-25.
Available from: https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03252957_v39_n1_p19_Vargas [ ]