Peinado, A.; Lizana, A.; Vidal, J.; Iemmi, C.; Campos, J. "Complete Stokes polarimeters based on liquid crystal displays" (2010) Optics and Photonics for Information Processing IV. 7797
El editor no permite incluir ninguna versión del artículo en el Repositorio.
Consulte el artículo en la página del editor
Consulte la política de Acceso Abierto del editor

Abstract:

In this work, we present the design, optimization and experimental implementation of complete Stokes polarimeters based on parallel aligned and twisted nematic liquid crystal displays. The liquid crystal elements are used as variable retarders whose retardance depends on the addressed voltage. By including this type of anisotropic devices in the polarimeter design we obtain some benefits when compared to mechanical polarimeters. For example, they allow to avoid the corresponding uncertainty due to mechanical movement. In addition, among the different polarimeter configurations provided by the polarimeter design, we have also applied an optimization procedure based on the minimization of different mathematical indicators (as the condition number or the equally weighted variance) in order to minimize the error amplification from the radiometric measurements to the solution. Finally, the optimized polarimeters are experimentally implemented and tested. In the implementation process, the eigenvalues method (a rigorous calibration procedure) is used. © 2010 SPIE.

Registro:

Documento: Conferencia
Título:Complete Stokes polarimeters based on liquid crystal displays
Autor:Peinado, A.; Lizana, A.; Vidal, J.; Iemmi, C.; Campos, J.
Ciudad:San Diego, CA
Filiación:Dept. de Física, Universitat Autònoma de Barcelona, Bellaterra 08193, Spain
ALBA Synchrotron Light Source Facility, Cerdanyola del Vallès 08290, Spain
Dept. de Física, Universidad de Buenos Aires, Buenos Aires 1428, Argentina
Palabras clave:Condition number; Equally weighted variance; LCD; Optimization; Parallel aligned; Polarimeter; Twisted nematic; Variable retarder; Condition numbers; Equally weighted variance; LCD; Parallel aligned; Twisted nematic; Variable retarder; Data processing; Design; Eigenvalues and eigenfunctions; Liquid crystal displays; Liquid crystals; Liquids; Nematic liquid crystals; Number theory; Optimization; Polarimeters
Año:2010
Volumen:7797
DOI: http://dx.doi.org/10.1117/12.860854
Título revista:Optics and Photonics for Information Processing IV
Título revista abreviado:Proc SPIE Int Soc Opt Eng
ISSN:0277786X
CODEN:PSISD
Registro:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_0277786X_v7797_n_p_Peinado

Referencias:

  • Twietmeyer, K.M., Chipman, R.A., Elsner Ann, E., Zhao, Y., Vannasdale, D., Mueller matrix retinal imager with optimized polarization conditions (2008) Opt. Express, 16 (26), pp. 21339-21354
  • Ramella-Roman, J.C., Duncan, D., Germer, T.A., Out-of-plane polarimetric imaging of skin: Surface and subsurface effects (2005) Proc. SPIE, 5686, pp. 142-153
  • Uribe-Patarroyo, N., Álvarez-Herrero, A., Heredero, R.L., Del Toro Iniesta, J.C., López Jiménez, A.C., Domingo, V., Gasent, J.L., Martínez Pillet, V., The IMaX Team IMaX: A polarimeter based on liquid crystal variable retarders for an aerospace mission (2008) Phys. Status Solidi C, 5, pp. 1041-1045
  • Márquez, A., Moreno, I., Iemmi, C., Lizana, A., Campos, J., Yzuel, M.J., Mueller-Stokes characterization and optimization of a liquid crystal on silicon display showing depolarization (2008) Opt. Express, 16 (3), pp. 1669-1685
  • Peinado, A., Lizana, A., Vidal, J., Iemmi, C., Campos, J., Optimization and performance criteria of a Stokes polarimeter based on two variable retarders (2010) Opt. Express, 18 (10), pp. 9815-9830
  • Garcia-Caurel, E., De Martino, A., Drévillon, B., Spectroscopic Mueller polarimeter based on liquid crystal devices (2004) Thin Solids Films, pp. 120-123. , 455-456
  • Bueno, J.M., Polarimetry using liquid-crystal variable retarders: Theory and calibration (2000) J. Opt. A: Pure Appl.Opt., 2 (3), pp. 216-222
  • De Martino, A., Kim, Y.K., Garcia-Caurel, E., Laude, B., Drévillon, B., Optimized Mueller polarimeter with liquid crystal (2003) Opt. Letters, 28 (8), pp. 616-618
  • Jones, R.C., A new calculus for the treatment of optical systems (1941) J. Opt. Soc. Am. A, 31 (7), pp. 488-493
  • Goldstein, D., (2003) [Polarized Light], , Marcel Dekker, NY
  • Taylor, P., (1974) [Theory and Applications of Numerical Analysis], , Academic Press, London
  • Sabatke, D.S., Descour, M.R., Dereniak, E.L., Sweatt, W.C., Kemme, S.A., Phipps, G.S., Optimization of retardance for a complete Stokes polarimeter (2000) Opt. Letters, 25 (11), pp. 802-804
  • Márquez, A., Campos, J., Yzuel, M.J., Moreno, I., Davis, J.A., Lemmi, C., Moreno, A., Robert, A., Characterization of edge effects in twisted-nematic liquid-crystal displays (2000) Opt. Eng., 39, pp. 3301-3307
  • Compain, E., Poirier, S., Drévillon, B., General and self-consistent method for the calibration of polarization modulators, polarimeters, and mueller-matrix ellipsometers (1999) Appl. Opt., 38 (16), pp. 3490-3502A4 - The Society of Photo-Optical Instrumentation Engineers (SPIE)

Citas:

---------- APA ----------
Peinado, A., Lizana, A., Vidal, J., Iemmi, C. & Campos, J. (2010) . Complete Stokes polarimeters based on liquid crystal displays. Optics and Photonics for Information Processing IV, 7797.
http://dx.doi.org/10.1117/12.860854
---------- CHICAGO ----------
Peinado, A., Lizana, A., Vidal, J., Iemmi, C., Campos, J. "Complete Stokes polarimeters based on liquid crystal displays" . Optics and Photonics for Information Processing IV 7797 (2010).
http://dx.doi.org/10.1117/12.860854
---------- MLA ----------
Peinado, A., Lizana, A., Vidal, J., Iemmi, C., Campos, J. "Complete Stokes polarimeters based on liquid crystal displays" . Optics and Photonics for Information Processing IV, vol. 7797, 2010.
http://dx.doi.org/10.1117/12.860854
---------- VANCOUVER ----------
Peinado, A., Lizana, A., Vidal, J., Iemmi, C., Campos, J. Complete Stokes polarimeters based on liquid crystal displays. Proc SPIE Int Soc Opt Eng. 2010;7797.
http://dx.doi.org/10.1117/12.860854