Abstract:
The eye suffers from aberrations that are pupil size dependent and reduce visual performance. Pupil size is often disregarded when visual performance is clinically determined. Considering 23 normal eyes, under natural viewing conditions, visual acuity is here related to pupil size when each subject reads monocularly a Snellen chart of constant luminance placed at 2m.
Registro:
Documento: |
Conferencia
|
Título: | Correlation between visual acuity and pupil size |
Autor: | Comastri, S.A.; Echarri, R.; Pfortner, T.; Marcano O. A.; Paz J.L. |
Ciudad: | Porlamar |
Filiación: | Lab. Optica, Dep. Física, Univ. Buenos Aires, 1428, Argentina Laboratorio Pfortner-Comealent, Buenos Aires, Argentina
|
Palabras clave: | Aberrations; Vision; Visual acuity; Aberrations; Image quality; Lenses; Neurology; Optical correlation; Optical systems; Polynomials; Surgery; Visualization; Wavefronts; Clinical practice; Pupil; Retina; Visual acuity; Vision |
Año: | 2004
|
Volumen: | 5622
|
Número: | PART 3
|
Página de inicio: | 1341
|
Página de fin: | 1346
|
DOI: |
http://dx.doi.org/10.1117/12.591637 |
Título revista: | RIAO/OPTILAS 2004: 5th Iberoamerican Meeting on Optics, and 8th Latin American Meeting on Optics, Lasers, and their Applications; ICO Regional Meeting
|
Título revista abreviado: | Proc SPIE Int Soc Opt Eng
|
ISSN: | 0277786X
|
CODEN: | PSISD
|
Registro: | https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_0277786X_v5622_nPART3_p1341_Comastri |
Referencias:
- Longhurst, R.S., (1973) Geometrical and Physical Optics, , Longman, London
- Born, M., Wolf, B., (1987) Principles of Optics, , Pergamon Press, Oxford
- Berson, F.G., (1993) Basic Ophthalmology for Medical Sttulents and Primary Care Residents,Am.Acad.Oph., , S.Francisco
- Roveda, J.M., Roveda, C.E., (1985) Manual De Oftalmología, , Lopez Libreros Editores, Buenos Aires
- Hopkins, H.H., Image formation by a general optical system. 1.General theory (1985) Applied Optics, 24, pp. 2491-2505
- Comastri, S.A., Simon, J.M., Blendowske, R., Generalized sine condition for image-forming systems with centering errors (1999) Journal Optical Society America A, 16 (3), pp. 602-611
- Thibos, L., Applegate, R., Schwiegerling, J., Webb, R., Standards for reporting the optical aberrations of eyes (2000) Vision Science and Its Applications, , Tops Volume 35
- Guirao, A., Gonzalez, C., Redondo, M., Geragbty, E., Norrby, S., Artal, P., Average optical performance of the human eye as a function of age in a normal population (1999) Investigative Ophthalmology and Visual Science, 40, pp. 203-213
- Marcos, S., Aberrations and visual performance following standard laser vision correction (2001) Journal of Refractive.Surgery, 17, pp. 596-601
- Comastri, S.A., Martin, G., Pfortner, T., Aberraciones de orden superior en la córnea del ojo humano (2003) Communication at the 88th Meeting of the Asociación Física Argentina
- Applegate, R., Hilmantel, G., Rowland, H., Tu, E., Starck, T., Zayac, J., Comeal first surface optical aberrations and visual performance (2000) Journal of Refractive Surgery, 16, pp. 507-514
- Paquin, M.P., Hamam, H., Simonet, P., The Julius F. Neumueller award in optics - Objective measurement of the optical aberrations for myopic eyes (2002) Optical and Vision Science, 79, pp. 285-291
- Guirao, A., Williams, D.R., Cox, I.G., Effect of rotation and translation on the expected benefit of an ideal method to correct the eye's higher order aberrations (2001) J. Optical Society America A, 18 (5), pp. 1003-1015
- Lin, X., Klette, G., Klette, R., Craig, J., Dean, S., Accurately measuring the size of the pupil of the eye (2003) Image and Vision Computing New Zealand, pp. 221-226
- Liang, J., Williams, D.R., Miller, D.T., Supernormal vision and high-resolution retinal imaging through adaptive optics (1997) Journal Optical Society of America A, 14 (11), pp. 2884-2892
- Barbero, S., Marcos, S., Merayo-Lloves, J., Barriuso, E.M., Validation of the estimation of comeal aberrations from videokeratography in keratoconus (2002) Journal of Refractive Surgery, 18, pp. 263-269
- Navarro, R., Nestares, O., Antona, B., Hemandez, J., Predicting visual acuity from measured ocular aberrations (2002) SPIE Proceedings of the 19th Meeting of the International Commission for Optics, pp. 971-972
- Haegerstrom-Portnoy, G., Brabyn, J., Schneck, M.E., Jampolsky, A., The skill card (1997) Inv.Oph..&Vis. Sci., 38, pp. 207-218A4 - Instituto Venezolano de Investigaciones Cientificas; Universidad Simon Bolivar; Universidad Central de Venezuela; Ministerio de ciencia y Tecnologia; Fundacion Polar
Citas:
---------- APA ----------
Comastri, S.A., Echarri, R., Pfortner, T., Marcano O. A. & Paz J.L.
(2004)
. Correlation between visual acuity and pupil size. RIAO/OPTILAS 2004: 5th Iberoamerican Meeting on Optics, and 8th Latin American Meeting on Optics, Lasers, and their Applications; ICO Regional Meeting, 5622(PART 3), 1341-1346.
http://dx.doi.org/10.1117/12.591637---------- CHICAGO ----------
Comastri, S.A., Echarri, R., Pfortner, T., Marcano O. A., Paz J.L.
"Correlation between visual acuity and pupil size"
. RIAO/OPTILAS 2004: 5th Iberoamerican Meeting on Optics, and 8th Latin American Meeting on Optics, Lasers, and their Applications; ICO Regional Meeting 5622, no. PART 3
(2004) : 1341-1346.
http://dx.doi.org/10.1117/12.591637---------- MLA ----------
Comastri, S.A., Echarri, R., Pfortner, T., Marcano O. A., Paz J.L.
"Correlation between visual acuity and pupil size"
. RIAO/OPTILAS 2004: 5th Iberoamerican Meeting on Optics, and 8th Latin American Meeting on Optics, Lasers, and their Applications; ICO Regional Meeting, vol. 5622, no. PART 3, 2004, pp. 1341-1346.
http://dx.doi.org/10.1117/12.591637---------- VANCOUVER ----------
Comastri, S.A., Echarri, R., Pfortner, T., Marcano O. A., Paz J.L. Correlation between visual acuity and pupil size. Proc SPIE Int Soc Opt Eng. 2004;5622(PART 3):1341-1346.
http://dx.doi.org/10.1117/12.591637