Abstract:

A method is presented for wavelength calibration of spectrofluorometer monochromators. It is based on the distortion that the characteristics absorption bands of glass filters (holmium or didymium oxide), commonly used for calibration of spectrophotometers, introduce in the emitted fluorescence of fluorophores like indole, diphenyl hexatriene, xylene or rhodamine 6G. Those filters or a well characterized absorber with sharp bands like benzene vapor can be used for the same purpose. The wavelength calibration accuracy obtained with this method is better than 0.1 nm, and requires no modification in the geometry of the spectrofluorometer sample compartment. © 1988.

Registro:

Documento: Artículo
Título:New methods for spectrofluorometer monochromator wavelength calibration
Autor:Paladini, A.A.; Erijman, L.
Filiación:INGEBI (UBA, FCEN-CONICET), Obligado 2490, 1428 Buenos Aires, Argentina
Palabras clave:Calibration; Didymium filter; Holmium filter; Instrumentation; Monochrmator; Wavelength; article; calibration; instrumentation; spectrofluorometry; standard; Calibration; Spectrometry, Fluorescence; Weights and Measures
Año:1988
Volumen:17
Número:1
Página de inicio:61
Página de fin:66
DOI: http://dx.doi.org/10.1016/0165-022X(88)90079-6
Título revista:Journal of Biochemical and Biophysical Methods
Título revista abreviado:J. Biochem. Biophys. Methods
ISSN:0165022X
CODEN:JBBMD
Registro:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_0165022X_v17_n1_p61_Paladini

Referencias:

  • Miller, Techniques in Visible and UV Spectrometry, vol. 2: Standards in Fluorescence Spectrometry (1981) Monochromator Wavelength Calibrations, , Chapman & Hall, New York, ch. 2
  • Mielenz, Optical Radiation Measurements, Vol. 3: Measurements of Photoluminescence, , Academic Press, New York
  • Chen, (1967) Anal. Biochem., 20, pp. 339-357
  • (1983) Annual Book of ASTM Standards, pp. 785-791. , ASTMA, Philadelphia, method E925-83
  • McNeirney, Slavin, (1962) Applied Optics, 1, pp. 365-367
  • Pye, (1969) Technical Manual, publ. No. 299184, (1). , Cambridge, England
  • Friedel, Orchin, (1951) Ultraviolet Spectra of Aromatic Compounds, , John Wiley and Sons, New York

Citas:

---------- APA ----------
Paladini, A.A. & Erijman, L. (1988) . New methods for spectrofluorometer monochromator wavelength calibration. Journal of Biochemical and Biophysical Methods, 17(1), 61-66.
http://dx.doi.org/10.1016/0165-022X(88)90079-6
---------- CHICAGO ----------
Paladini, A.A., Erijman, L. "New methods for spectrofluorometer monochromator wavelength calibration" . Journal of Biochemical and Biophysical Methods 17, no. 1 (1988) : 61-66.
http://dx.doi.org/10.1016/0165-022X(88)90079-6
---------- MLA ----------
Paladini, A.A., Erijman, L. "New methods for spectrofluorometer monochromator wavelength calibration" . Journal of Biochemical and Biophysical Methods, vol. 17, no. 1, 1988, pp. 61-66.
http://dx.doi.org/10.1016/0165-022X(88)90079-6
---------- VANCOUVER ----------
Paladini, A.A., Erijman, L. New methods for spectrofluorometer monochromator wavelength calibration. J. Biochem. Biophys. Methods. 1988;17(1):61-66.
http://dx.doi.org/10.1016/0165-022X(88)90079-6