Artículo

Estamos trabajando para incorporar este artículo al repositorio
Consulte el artículo en la página del editor
Consulte la política de Acceso Abierto del editor

Abstract:

This study aimed to characterize the following: (i) in chronically hemodialyzed subjects (CHDSs), with and without diabetic nephropathy (DN), and in healthy subjects (non-CHDSs) different arterial pathways stiffness to determine potential pathology-dependent, etiology- and/or pathway-dependent differences; and (ii) the biomechanical mismatch (BM) between arteries from non-CHDSs or CHDSs (with and without DN) and arterial cryografts, venous cryografts, and synthetic prosthesis to determine arterial pathway, pathology, and/or etiology-related differences in the substitute of election in terms of BM. Carotid-femoral and carotid-brachial pulse wave velocity (PWV) were measured in 30 non-CHDSs and 71 CHDSs (11 with DN). In addition, PWV was measured in arterial (elastic and muscular) and venous cryografts and in expanded polytetrafluorethylene prosthesis. The arterial pathways regional differences and the subjects' arterial pathways-substitutes BM were calculated. Arterial stiffness levels and regional differences were higher in CHDS than in non-CHDS. Among CHDS, those with DN showed higher stiffness in the aorto-femoral pathway and larger regional differences. Cryografts showed always the least BM. Non-CHDS and CHDS differed in the cryograft of election. In CHDS, the BM was related with the cryograft type, arterial pathway, and renal disease etiology. The BM could be minimized, selecting the most adequate cryograft type, taking into account the recipient specific characteristic (i.e., arterial pathway and renal disease etiology). © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

Registro:

Documento: Artículo
Título:Vascular cryografts offer better biomechanical properties in chronically hemodialyzed patients: Role of cryograft type, arterial pathway, and diabetic nephropathy as matching determinants: Thoughts and progress
Autor:Zócalo, Y.; Bia, D.; Armentano, R.L.; Galli, C.; Pérez, H.; Saldías, M.; Álvarez, I.; Valtuille, R.; Cabrera-Fischer, E.
Filiación:Departamento de Fisiología, Facultad de Medicina, Universidad de la República, Uruguay
Instituto Nacional de Donación y Transplante de Células, Tejidos y Órganos, MSP-Universidad de la República, Montevideo, Uruguay
Universidad Tecnológica Nacional, Argentina
Facultad de Ingeniería y Ciencias Exactas y Naturales, Universidad Favaloro, Argentina
CONICET, Buenos Aires, Argentina
Idioma: Inglés
Palabras clave:Biomechanical mismatch; Diabetic nephropathy; Hemodialysis; Human vascular homografts; Pulse wave velocity; politef; adult; arterial stiffness; artery prosthesis; article; biomechanics; brachial artery; carotid artery pulse; clinical feature; diabetic nephropathy; disease association; femoral artery; hemodialysis patient; human; human tissue; major clinical study; priority journal; pulse wave; vascular cryograft; Aged; Arteries; Biomechanics; Blood Vessel Prosthesis; Cryopreservation; Diabetic Nephropathies; Elasticity; Humans; Kidney Failure, Chronic; Middle Aged; Polytetrafluoroethylene; Pulse; Renal Dialysis; Transplants
Año:2010
Volumen:34
Número:8
Página de inicio:677
Página de fin:684
DOI: http://dx.doi.org/10.1111/j.1525-1594.2009.00962.x
Título revista:Artificial Organs
Título revista abreviado:Artif. Organs
ISSN:0160564X
CODEN:ARORD
CAS:politef, 9002-84-0, 9039-02-5; Polytetrafluoroethylene, 9002-84-0
Registro:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_0160564X_v34_n8_p677_Zocalo

Referencias:

  • Konner, K., Nonnast-Daniel, B., Ritz, E., The arteriovenous fistula (2003) J Am Soc Nephrol, 14, pp. 1669-1680
  • Roy-Chaudhury, P., Kelly, B.S., Narayana, A., Hemodialysis vascular access dysfunction from basic biology to clinical intervention (2002) Adv Ren Replace Ther, 9, pp. 74-84
  • Trubel, W., Schima, H., Moritz, A., Compliance mismatch and formation of distal anastomotic intimal hyperplasia in externally stiffened and lumen-adapted venous grafts (1995) Eur J Vasc Endovasc Surg, 10, pp. 415-423
  • Haruguchi, H., Teraoka, S., Intimal hyperplasia and hemodynamic factors in arterial bypass and arteriovenous grafts: A review (2003) J Artif Organs, 6, pp. 227-235
  • Bia, D., Zócalo, Y., Pessana, F., Femoral arteries energy dissipation and filtering function remain unchanged after cryopreservation procedure (2005) Transpl Int, 18, pp. 1346-1355
  • Bia, D., Pessana, F., Armentano, R., Cryopreservation procedure does not modify human carotid homografts mechanical properties: An isobaric and dynamic analysis (2006) Cell Tissue Bank, 7, pp. 183-194
  • Bia, D., Zócalo, Y., Pessana, F., Differential functional coupling between human saphenous cryoallografts and arteries: Importance of the arterial type and the biomechanical parameter evaluated (2007) Artif Organs, 31, pp. 809-818
  • Bia, D., Armentano, R.L., Zócalo, Y., Functional properties of fresh and cryopreserved carotid and femoral arteries, and of venous and synthetic grafts: Comparison with arteries from normotensive and hypertensive patients (2007) Cell Tissue Bank, 8, pp. 43-57
  • Madden, R.L., Lipkowitz, G.S., Browne, B.J., Kurbanov, A., Experience with cryopreserved cadaveric femoral vein allografts used for hemodialysis access (2004) Ann Vasc Surg, 18, pp. 453-458
  • Lin, P.H., Brinkman, W.T., Terramani, T.T., Lumsden, A.B., Management of infected hemodialysis access grafts using cryopreserved human vein allografts (2002) Am J Surg, 184, pp. 31-6
  • Takamoto, S., Nakajima, S., Okita, Y., Cryopreserved femoral arterial allografts for vascular access in hemodialysis (1998) Transpl Proc, 30, pp. 3917-3919
  • Kornowski, R., Mintz, G.S., Kent, K.M., Increased restenosis in diabetes mellitus after coronary interventions is due to exaggerated intimal hyperplasia. A serial intravascular ultrasound study (1997) Circulation, 95, pp. 1366-1369
  • Davies, M.G., Kim, J.H., Klyachkin, M.L., Diabetes mellitus and experimental vein graft structure and function (1994) J Vasc Surg, 19, pp. 1031-1043
  • Laurent, S., Cockcroft, J., Van Bortel, L., European network for non-invasive investigation of large arteries. Expert consensus document on arterial stiffness: Methodological issues and clinical applications (2006) Eur Heart J, 27, pp. 2588-2605
  • Blacher, J., Demuth, K., Guerin, A.P., Safar, M.E., Moatti, N., London, G.M., Influence of biochemical alterations on arterial stiffness in patients with end-stage renal disease (1998) Arteriosclerosis, Thrombosis, and Vascular Biology, 18 (4), pp. 535-541
  • Cameron, J.D., Bulpitt, C.J., Pinto, E.S., Rajkumar, C., The aging of elastic and muscular arteries: A comparison of diabetic and nondiabetic subjects (2003) Diabetes Care, 26, pp. 2133-2138
  • Aoun, S., Blacher, J., Safar, M., Mourad, J.J., Diabetes mellitus and renal failure: Effects on large artery stiffness (2001) J Hum Hypertens, 15, pp. 693-700
  • Shoji, T., Emoto, M., Shinohara, K., Diabetes mellitus, aortic stiffness, and cardiovascular mortality in end-stage renal disease (2001) J Am Soc Nephrol, 12, pp. 2117-2124
  • Cabrera-Fischer, E.I., Bia, D., Cassanello, G.L., Reduced elastic mismatch achieved by interposing vein cuff in expanded polytetrafluoroethylene femoral bypass decreases intimal hyperplasia (2005) Artif Organs, 29, pp. 122-130
  • Mall, J.W., Philipp, A.W., Rademacher, A., Paulitschke, M., Büttemeyer, R., Re-endothelialization of punctured ePTFE graft: An in vitro study under pulsed perfusion conditions (2004) Nephrol Dial Transpl, 19, pp. 61-7

Citas:

---------- APA ----------
Zócalo, Y., Bia, D., Armentano, R.L., Galli, C., Pérez, H., Saldías, M., Álvarez, I.,..., Cabrera-Fischer, E. (2010) . Vascular cryografts offer better biomechanical properties in chronically hemodialyzed patients: Role of cryograft type, arterial pathway, and diabetic nephropathy as matching determinants: Thoughts and progress. Artificial Organs, 34(8), 677-684.
http://dx.doi.org/10.1111/j.1525-1594.2009.00962.x
---------- CHICAGO ----------
Zócalo, Y., Bia, D., Armentano, R.L., Galli, C., Pérez, H., Saldías, M., et al. "Vascular cryografts offer better biomechanical properties in chronically hemodialyzed patients: Role of cryograft type, arterial pathway, and diabetic nephropathy as matching determinants: Thoughts and progress" . Artificial Organs 34, no. 8 (2010) : 677-684.
http://dx.doi.org/10.1111/j.1525-1594.2009.00962.x
---------- MLA ----------
Zócalo, Y., Bia, D., Armentano, R.L., Galli, C., Pérez, H., Saldías, M., et al. "Vascular cryografts offer better biomechanical properties in chronically hemodialyzed patients: Role of cryograft type, arterial pathway, and diabetic nephropathy as matching determinants: Thoughts and progress" . Artificial Organs, vol. 34, no. 8, 2010, pp. 677-684.
http://dx.doi.org/10.1111/j.1525-1594.2009.00962.x
---------- VANCOUVER ----------
Zócalo, Y., Bia, D., Armentano, R.L., Galli, C., Pérez, H., Saldías, M., et al. Vascular cryografts offer better biomechanical properties in chronically hemodialyzed patients: Role of cryograft type, arterial pathway, and diabetic nephropathy as matching determinants: Thoughts and progress. Artif. Organs. 2010;34(8):677-684.
http://dx.doi.org/10.1111/j.1525-1594.2009.00962.x