Abstract:
A steady-state method for thermal conductivity measurements above 100 K on poor conductors is described. Radiation errors are made negligible using a closely fitting shield with a temperature profile matched along its length to that of the sample. Calculations show that for a typical geometry, the radiation error at room temperature is two or three orders of magnitude lower than for a shield kept at the sink temperature. The experimental setup is described and measurements on PMMA are reported. The results agree with measurements reported by other authors who use completely different methods.
Referencias:
- Klein, M.V., Caldwell, R.F., (1966) Rev. Sci. Instrum., 37, p. 1291
- Slack, G.A., (1961) Phys. Rev., 122, p. 1451
- Andersson, P., Bäckström, G., (1976) Rev. Sci. Instrum., 47, p. 205
- Gustafsson, S.E., Karawacki, E., (1983) Rev. Sci. Instrum., 54, p. 744
- Cahill, D.G., Pohl, R.O., (1987) Phys. Rev. B, 35, p. 4067. , references therein
- Birge, N.O., (1986) Phys. Rev. B, 34, p. 1631
- Eiermann, K., (1961) Kunststoffe, 51, p. 512
- Parrott, J.E., Stuckes, A.D., (1975) Thermal Conductivity of Solids, p. 14. , (Pion, London)
- Ditmar, D.A., Ginnings, D.C., (1957) J. Res. Nat. Bur. Stand., 59, p. 93
- Powell, R.W., Tye, R.P., (1960) Engineer, 209, p. 729
- Ashworth, T., Johnson, L.R., Hsiung, C.Y., Kreitmann, M.M., (1973) Cryogenics, 13, p. 34
- (1969) Thermal Conductivity, , R. P. Tye, Ed, (Academic, New York), Vol. l, p. 111
- Talpe, J.H., Bekeris, V.I., Acha, C., (1990) Am. J. Phys., 58, p. 379
- , p. 158. , Ref. 12, This feature is not included in the Laubitz computerized model; , p. 121. , This is true even for [Formula Omitted] if only radial radiant-heat transfer is admitted, an assumption implied by the approximation made by Laubitz, Ref. 12, p. Eq. 32; Sala, A., (1986) Radiant Properties of Materials, , (Elsevier, New York)
- Talpe, J.H., Stolovitzky, G.A., Bekeris, V.I., (1987) Cryogenics, 27, p. 693
- Eiermann, K., Hellwege, K.H., (1962) J. Polym. Sci., 57, p. 99
- Choy, C.L., Salinger, G.L., Chiang, Y.C., (1970) J. Appl. Phys., 41, p. 597
- Stephens, R.B., Cieloszyk, G.S., Salinger, G.L., (1972) Phys. Lett., 38A, p. 215
- Choy, C.L., (1977) Polymer, 18, p. 984
Citas:
---------- APA ----------
Talpe, J.H., Bekeris, V.I., Sanchez, M.J. & Simonelli, G.
(1991)
. Reduction of radiation errors in thermal conductivity measurements above 100 K. Review of Scientific Instruments, 62(4), 1054-1056.
http://dx.doi.org/10.1063/1.1142057---------- CHICAGO ----------
Talpe, J.H., Bekeris, V.I., Sanchez, M.J., Simonelli, G.
"Reduction of radiation errors in thermal conductivity measurements above 100 K"
. Review of Scientific Instruments 62, no. 4
(1991) : 1054-1056.
http://dx.doi.org/10.1063/1.1142057---------- MLA ----------
Talpe, J.H., Bekeris, V.I., Sanchez, M.J., Simonelli, G.
"Reduction of radiation errors in thermal conductivity measurements above 100 K"
. Review of Scientific Instruments, vol. 62, no. 4, 1991, pp. 1054-1056.
http://dx.doi.org/10.1063/1.1142057---------- VANCOUVER ----------
Talpe, J.H., Bekeris, V.I., Sanchez, M.J., Simonelli, G. Reduction of radiation errors in thermal conductivity measurements above 100 K. 1991;62(4):1054-1056.
http://dx.doi.org/10.1063/1.1142057