Artículo

Bosch, H.E.; Davidson, J.; Fariolli, M.A.; Silbergleit, V. "Semiconductor detectors setup for nuclear spectroscopy studies" (1974) Nuclear Instruments and Methods. 117(1):213-219
Estamos trabajando para incorporar este artículo al repositorio
Consulte el artículo en la página del editor
Consulte la política de Acceso Abierto del editor

Abstract:

Two setups of semiconductor detectors were employed. For the detection of gamma rays, a commercial Ge(Li) counter was used. For the detection of low-energy X rays, internal conversion electrons, and beta continuum spectra, a Si(Li) counter was mounted in a cryostat, the configuration of which is given. Both detectors were used to study the decay of 115Cd (53.5 h). New results are reported concerning the ICC, beta spectra and low-energy X-ray spectra. © 1974.

Registro:

Documento: Artículo
Título:Semiconductor detectors setup for nuclear spectroscopy studies
Autor:Bosch, H.E.; Davidson, J.; Fariolli, M.A.; Silbergleit, V.
Filiación:Laboratorio de Radiaciones, Departamento de Física, Facultad de Ciencias Exactas y Naturales, Buenos Aires, Argentina
Año:1974
Volumen:117
Número:1
Página de inicio:213
Página de fin:219
DOI: http://dx.doi.org/10.1016/0029-554X(74)90399-1
Título revista:Nuclear Instruments and Methods
ISSN:0029554X
Registro:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_0029554X_v117_n1_p213_Bosch

Referencias:

  • Heath, (1957) Scintillation spectrometry gamma-ray catalogue, , Philips Petroleum Co., Atomic Energy Division, Idaho Falls, Idaho
  • Charoenkwan, Studies of beta spectra using a solid state spectrometer (1965) Nuclear Instruments and Methods, 34, p. 96
  • Graeffe, Tang, Coryell, Gordon, (1966) Phys. Rev., 149, p. 884
  • Hans, Rao, (1963) Nucl. Phys., 44, p. 320
  • Campbell, Kirk, The K-conversion coefficient of the 35.6 keV transition in115In (1969) Canadian Journal of Physics, 47, p. 1257
  • McDonald, Porter, Stewart, (1967) Nucl. Phys., 104 A, p. 177
  • Abecasis, Krmpotić, (1970) Nucl. Phys., 151 A, p. 641
  • Szybisz, (1972) Thesis, , Universidad de Buenos Aires
  • Kevex catalogue

Citas:

---------- APA ----------
Bosch, H.E., Davidson, J., Fariolli, M.A. & Silbergleit, V. (1974) . Semiconductor detectors setup for nuclear spectroscopy studies. Nuclear Instruments and Methods, 117(1), 213-219.
http://dx.doi.org/10.1016/0029-554X(74)90399-1
---------- CHICAGO ----------
Bosch, H.E., Davidson, J., Fariolli, M.A., Silbergleit, V. "Semiconductor detectors setup for nuclear spectroscopy studies" . Nuclear Instruments and Methods 117, no. 1 (1974) : 213-219.
http://dx.doi.org/10.1016/0029-554X(74)90399-1
---------- MLA ----------
Bosch, H.E., Davidson, J., Fariolli, M.A., Silbergleit, V. "Semiconductor detectors setup for nuclear spectroscopy studies" . Nuclear Instruments and Methods, vol. 117, no. 1, 1974, pp. 213-219.
http://dx.doi.org/10.1016/0029-554X(74)90399-1
---------- VANCOUVER ----------
Bosch, H.E., Davidson, J., Fariolli, M.A., Silbergleit, V. Semiconductor detectors setup for nuclear spectroscopy studies. 1974;117(1):213-219.
http://dx.doi.org/10.1016/0029-554X(74)90399-1