Abstract:
A microbial sensor based on a carbon dioxide electrode coupled with immobilized Saccharomyces cerevisiae (baker's yeast) has been used for the determination of sucrose in dairy products. The sensor was used as the detector in a flow injection analysis system. Calibration curves for sucrose were established from 1 to 100 g/l. Determinations for several dairy products containing added sucrose gave good agreement with the concentrations given by manufacturers. Typically, the SE of the method was shown to be < 5 % of the calculated mean.
Referencias:
- Alais, C., (1984) Science du Lait. Principes des Techniques Laitières, 4th Edn., , Paris: SEPAIC
- Barnett, J.A., The utilization of sugars by yeasts (1976) Advances in Carbohydrate Chemistry and Biochemistry, 32, pp. 125-234
- De María, C.G., Townshend, A., A sequential determination of glucose, fructose and sucrose by flow injection analysis with immobilized enzyme reactors and spectrophotometric detection (1992) Analytica Chimica Acta, 261, pp. 137-143
- Deshpande, S.S., Rocco, R.M., Biosensors and their potential use in food quality control (1994) Food Technology, 48 (6), pp. 146-150
- Greenway, G.M., Kometa, N., The determination of sugars in beverages and medicine using on-line dialysis for sample preparation (1995) Food Chemistry, 53, pp. 105-110
- Lee, S.J., Saleemuddin, M., Scheper, T., Loos, H., Sahm, H., A fluorimetric fiber-optic biosensor for dual analysis of glucose and fructose using glucose-fructose-oxidoreductase isolated from Zymomonas mobilis (1994) Journal of Biotechnology, 36, pp. 39-44
- Mascini, M., Memoli, A., Comparison of microbial sensors based on amperometric and potentiometric electrodes (1986) Analytica Chimica Acta, 182, pp. 113-122
- Park, J.K., Shin, M.C., Lee, S.G., Kim, H.S., Flow injection analysis of glucose, fructose, and sucrose using a biosensor constructed with permeabilized Zymomonas mobilis and invertase (1995) Biotechnology Progress, 11, pp. 58-63
- Satoh, I., Karube, I., Susuki, S., Enzyme electrode for sucrose (1976) Biotechnology and Bioengineering, 18, pp. 269-272
- Severinghaus, J.W., Bradley, A.F., Electrodes for blood pO2 and pC02 determintation (1958) Journal of Applied Physiology, 13, pp. 515-520
- Xu, Y., Guibault, G.G., Kuan, S.S., Sucrose enzyme electrode (1989) Analytical Chemistry, 61, pp. 782-784
Citas:
---------- APA ----------
Cortón, E. & Locascio, G.
(1998)
. Simple flow injection analysis system for determination of added sugars in dairy products. Journal of Dairy Research, 65(4), 675-680.
http://dx.doi.org/10.1017/S0022029998003045---------- CHICAGO ----------
Cortón, E., Locascio, G.
"Simple flow injection analysis system for determination of added sugars in dairy products"
. Journal of Dairy Research 65, no. 4
(1998) : 675-680.
http://dx.doi.org/10.1017/S0022029998003045---------- MLA ----------
Cortón, E., Locascio, G.
"Simple flow injection analysis system for determination of added sugars in dairy products"
. Journal of Dairy Research, vol. 65, no. 4, 1998, pp. 675-680.
http://dx.doi.org/10.1017/S0022029998003045---------- VANCOUVER ----------
Cortón, E., Locascio, G. Simple flow injection analysis system for determination of added sugars in dairy products. J. Diary Res. 1998;65(4):675-680.
http://dx.doi.org/10.1017/S0022029998003045