Artículo

El editor solo permite decargar el artículo en su versión post-print desde el repositorio. Por favor, si usted posee dicha versión, enviela a
Consulte el artículo en la página del editor
Consulte la política de Acceso Abierto del editor

Abstract:

The elution behaviour of different polymer-solvent systems in three types of organic columns for SEC has been compared and interpreted. The experimental data show that the classical universal calibration is not accomplished. Deviations from a unique curve are observed due to the binary and ternary interactions between the components of the system (solvent, polymer and gel) which results on secondary mechanisms accompanying the main pure or "ideal" SEC separation mechanism. Both, enthalpic and entropic effects are interpreted in terms of the swelling and crosslinking degrees of the gel packings, and are also related with the fractal characteristics of their surfaces, such as the fractal dimension and the available pore size. Moreover, a relationship between the fractal dimension of the pore surface and the chromatographic distribution coefficient is proposed. © 2003 Elsevier Science B.V. All rights reserved.

Registro:

Documento: Artículo
Título:Fractal calibration in size-exclusion chromatography: I. An introduction
Autor:García-Lopera, R.; Irurzun, I.; Abad, C.; Campos, A.
Filiación:Dept. de Quím. Física, Inst. de Cié. dels Materials, Universitat de València, E-46100 Burjassot, València, Spain
Departamento de Física, Universidad de Buenos Aires, Ciudad de Buenos Aires, Argentina
Dept. de Bioquim. i Biol. Molec., Universitat de València, València, Spain
Department of Chemistry, University of Cambridge, Cambridge, United Kingdom
Palabras clave:Calibration; Fractal calibration; Organic gel packings; Polymers; Universal calibration; Crosslinking; Entropy; Fractals; Gels; Polymers; Pore size; Solvents; Chromatographic distribution coefficients; Size exclusion chromatography; organic compound; polymer; solvent; article; calibration; channel gating; chemical interaction; chromatography; column chromatography; cross linking; data analysis; elution; enthalpy; entropy; experimental test; fractal analysis; gel; gel permeation chromatography; observation; priority journal; regulatory mechanism; separation technique
Año:2003
Volumen:996
Número:1-2
Página de inicio:33
Página de fin:43
DOI: http://dx.doi.org/10.1016/S0021-9673(03)00609-5
Título revista:Journal of Chromatography A
Título revista abreviado:J. Chromatogr. A
ISSN:00219673
CODEN:JCRAE
Registro:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_00219673_v996_n1-2_p33_GarciaLopera

Referencias:

  • Benoit, H., Grubisic, Z., Rempp, P., Decker, D., Zilliox, J.G., (1966) J. Chim. Phys., 63, p. 1507
  • Grubisic, Z., Rempp, P., Benoit, H., (1967) J. Polym. Sci. Polym. Lett., 5, p. 753
  • Mori, S., Barth, H.G., (1999) Size Exclusion Chromatography, , Berlin: Springer
  • Campos, A., Soria, V., Figueruelo, J.E., (1979) Makromol. Chem., 180, p. 1961
  • Figueruelo, J.E., Campos, A., Soria, V., (1981) Makromol. Chem., 182, p. 1525
  • Berek, D., (1999) Column Handbook for Size Exclusion Chromatography, pp. 445-457. , London: Academic Press. Chapter 15
  • Gómez, C.M., García, R., Figueruelo, J.E., Campos, A., (2000) Macromol. Chem. Phys., 201, p. 2354
  • García, R., Gómez, C.M., Figueruelo, J.E., Campos, A., (2001) Macromol. Chem. Phys., 202, p. 1889
  • (1998) American Chemical Society Symp. Ser. 367, , R.A. Dickie, S.S. Labana, Bauer R.S
  • García, R., Recalde, I.B., Figueruelo, J.E., Campos, A., (2001) Macromol. Chem. Phys., 202, p. 3352
  • García-Lopera, R., Gómez, C.M., Abad, C., Campos, A., (2002) Macromol. Chem. Phys., 203, p. 2551
  • Brochard, F., (1985) J. Phys., 46, p. 2117
  • Brochard, F., Ghazi, A., Le Maire, M., Martin, M., (1989) Chromatographia, 27, p. 257
  • Eisenriegler, E., (1993) Polymers Near Surfaces, , Singapore: World Scientific
  • Fleer, G.J., (1993) Polymers at Interfaces, , London: Chapman & Hall
  • Garel, T., Orland, H., (1997) Phys. Rev. B, 55, p. 226
  • Guillaume, Y.C., Robert, J.F., Guinchard, C., (2001) Anal. Chem., 73, p. 3059
  • Duca, D., Deganello, G., (1996) J. Mol. Catal. A Chem., 112, p. 413
  • Huber, G., Vilgis, T.A., (1998) Eur. Phys. J. B, 3, p. 217
  • Bakos, D., Bleha, T., Ozima, A., Berek, D., (1979) J. Appl. Polym. Sci., 23, p. 2233
  • Belenkii, B.G., Vilenchik, L.Z., (1983) Modern Liquid Chromatography of Macromolecules, , Amsterdam: Elsevier
  • García, R., Porcar, I., Campos, A., Soria, V., Figueruelo, J.E., (1993) J. Chromatogr. A, 655, p. 191
  • Campos, A., García, R., Porcar, I., Soria, V., (1994) J. Liq. Chromatogr., 17, p. 3261
  • Shah, G., Dubin, P.L., (1995) J. Chromatogr. A, 693, p. 197
  • García, R., Porcar, I., Figueruelo, J.E., Soria, V., Campos, A., (1996) J. Chromatogr. A, 721, p. 203
  • Berek, D., Janco, M., Meira, G.R., (1998) J. Polym. Sci. Part A: Polym. Chem., 36, p. 1363
  • Kosmas, M.K., Bokaris, E.P., Georgaka, E.G., (1998) Polymer, 39, p. 4973
  • Yau, W.W., Kirkland, J.J., Bly, D.D., (1979) Modern Size Exclusion Chromatography, , New York: Wiley
  • Dawkins, J.V., Hemming, M., (1975) Makromol. Chem., 176, p. 1795
  • Le Maire, M., Ghazi, A., Martin, M., Brochard, F., (1989) J. Biochem., 106, p. 814
  • Campos, A., Gómez, C.M., García, R., Figueruelo, J.E., Soria, V., (1996) Polymer, 37, p. 3361
  • Gómez, C.M., Figueruelo, J.E., Campos, A., (1998) Polymer, 39, p. 4023
  • Gómez, C.M., Figueruelo, J.E., Campos, A., (1999) Macromol. Chem. Phys., 200, p. 246
  • García, R., Gómez, C.M., Codoñer, A., Abad, C., Campos, A., (2003) J. Biochem. Biophys. Methods, 1689, p. 1
  • Kato, Y., Hashimoto, T., (1974) J. Appl. Polym. Sci., 18, p. 1239
  • Bleha, T., Bakos, D., Berek, D., (1977) Polymer, 18, p. 897
  • Campos, A., Borque, L., Figueruelo, J.E., (1978) Anal. Quím., 74, p. 701
  • Figueruelo, J.E., Campos, A., Soria, V., Tejero, R., (1984) J. Liq. Chromatogr., 7, p. 1061
  • Janca, J., (1977) J. Chromatogr., 134, p. 263
  • Verdú, P., (2001), B.Sc. Project, University of Valencia, Spain; Porcar, I., García, R., Soria, V., Campos, A., Figueruelo, J.E., (1992) J. Non-Cryst. Solids, 147-148, p. 170
  • Column Catalogues Millipore-Waters and Teknokroma (1999-2000)

Citas:

---------- APA ----------
García-Lopera, R., Irurzun, I., Abad, C. & Campos, A. (2003) . Fractal calibration in size-exclusion chromatography: I. An introduction. Journal of Chromatography A, 996(1-2), 33-43.
http://dx.doi.org/10.1016/S0021-9673(03)00609-5
---------- CHICAGO ----------
García-Lopera, R., Irurzun, I., Abad, C., Campos, A. "Fractal calibration in size-exclusion chromatography: I. An introduction" . Journal of Chromatography A 996, no. 1-2 (2003) : 33-43.
http://dx.doi.org/10.1016/S0021-9673(03)00609-5
---------- MLA ----------
García-Lopera, R., Irurzun, I., Abad, C., Campos, A. "Fractal calibration in size-exclusion chromatography: I. An introduction" . Journal of Chromatography A, vol. 996, no. 1-2, 2003, pp. 33-43.
http://dx.doi.org/10.1016/S0021-9673(03)00609-5
---------- VANCOUVER ----------
García-Lopera, R., Irurzun, I., Abad, C., Campos, A. Fractal calibration in size-exclusion chromatography: I. An introduction. J. Chromatogr. A. 2003;996(1-2):33-43.
http://dx.doi.org/10.1016/S0021-9673(03)00609-5