Artículo

Estamos trabajando para incorporar este artículo al repositorio
Consulte el artículo en la página del editor
Consulte la política de Acceso Abierto del editor

Abstract:

A chemometric method has been applied for the determination of the free fatty acid (FFA) concentration in commercial olive oil samples of different types an origins by using Fourier transform infrared spectroscopy (FTIR) attenuated total reflectance (ATR) measurements. Different methods for selecting the training set, including hierarchical cluster analysis, were applied and compared. The prediction capabilities of partial least squares (PLS) multivariate calibration methods, net analyte signal (NAS) preprocessing followed by PLS or classical least squares (CLS) regression method of ATR-FTIR data were evaluated. Several aspects, like spectral range to be considered, different preprocessing alternatives (mean centering, multiplicative scattering correction, standard normal variate (SNV)), together with a critical evaluation of the calibration set were made on using the mean square error of cross-validation and prediction, as control parameters. Using a calibration set of 16 samples the properties of 28 samples were predicted with relative precision of triplicates of 0.017wt.%. The mean difference between predicted and actual values and the standard deviation of mean differences were -0.001 and 0.037wt.%, respectively. The limit of detection (LOD), sensitivity and selectivity of the methodology developed were evaluated in terms of the net analyte signal, being found a limit of detection of 0.072wt.%, a sensitivity value of 0.077 in terms of analytical signal per unit of concentration, being expressed that in wt.%, and a linear relationship (R2=0.9963) between selectivity and FFA concentration (equivalent to 0.24% for a sample containing 1wt.% of FFA). © 2003 Elsevier B.V. All rights reserved.

Registro:

Documento: Artículo
Título:Selection of calibration set samples in determination of olive oil acidity by partial least squares-attenuated total reflectance-Fourier transform infrared spectroscopy
Autor:Iñón, F.A.; Garrigues, J.M.; Garrigues, S.; Molina-Díaz, A.; De La Guardia, M.
Filiación:Lab. Análisis de Trazas, Depto. de Quím. Inorg., Ciudad Universitaria, 1428 Buenos Aires, Argentina
Depto. de Quim. Analitica, Facultad de Química, Universidad de Valencia, Edif. Jeroni Munoz C/ Dr. Moliner 50, E-46100 Burjassot, Valencia, Spain
Depto. Quim. Fis. y Quim. Analitica, Universidad de Jaén, Jaén, Spain
Palabras clave:ATR; Cluster analysis; FTIR; Oil analysis; Partial least squares; Training set sample selection; Fatty acids; Fourier transform infrared spectroscopy; Least squares approximations; Olive oils; Vegetable oils; fatty acid; olive oil; accuracy; acidity; analytical error; article; calibration; chemometric analysis; cluster analysis; comparative study; concentration (parameters); fatty acid analysis; infrared spectroscopy; prediction; priority journal; reflectometry; regression analysis
Año:2003
Volumen:489
Número:1
Página de inicio:59
Página de fin:75
DOI: http://dx.doi.org/10.1016/S0003-2670(03)00711-6
Título revista:Analytica Chimica Acta
Título revista abreviado:Anal. Chim. Acta
ISSN:00032670
CODEN:ACACA
CAS:olive oil, 8001-25-0
Registro:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_00032670_v489_n1_p59_Inon

Referencias:

  • Massart, D.L., Vandeginste, B.G.M., Buydens, L.M.C., De Jong, S., Lewi, P.J., Verbeke, J., (1997) Handbook of Chemometrics and Qualimetrics, Parts A and B, , Elsevier, Amsterdam
  • Brereton, R.G., (2000) Analyst, 125, p. 2125
  • Valcarcel, M., Gallego, M., Cardenas, S., Pena, F., (2002) Grasas Aceites, 53, p. 1
  • (1989), Official Methods and Recommendered Practices of the American Oil Chemists' Society, fourth ed., American Oil Chemists' Society, Champaign, IL; Ismail, A.A., Vandevoort, F.R., Emo, G., Sedman, J., (1993) J. Am. Oil Chem. Soc., 70, p. 335
  • Canham, J.S., Pacey, G.E., (1987) J. Am. Oil Chem. Soc., 64, p. 1004
  • Zhi, Z.P., Rios, A., Valcarcel, M., (1996) Anal. Chim. Acta, 318, p. 187
  • Nouros, P.G., Georgiou, C.A., Polissiou, M.G., (1997) Anal. Chim. Acta, 351, p. 291
  • Canada, M.J.A., Medina, A.R., Lendl, B., (2001) Appl. Spectrosc., 55, p. 356
  • Bertran, E., Blanco, M., Coello, J., Iturriaga, H., Maspoch, S., Montoliu, I., (1999) J. Am. Oil Chem. Soc., 76, p. 611
  • Verleyen, T., Verhe, R., Cano, A., Huyghebaert, A., De Greyt, W., (2001) J. Am. Oil Chem. Soc., 78, p. 981
  • Man, Y.B.C., Setiowaty, G., (1999) Food Chem., 66, p. 109
  • Ferre, J., Rius, F.X., (1996) Anal. Chem., 68, p. 1565
  • Barnes, R.J., Dhanoa, M.S., Lister, S.J., (1989) Appl. Spectrosc., 43, p. 772
  • Boschetti, C.E., Olivieri, A.C., (2001) J. Near Infrared Spectrosc., 9, p. 245
  • González, A.G., Herrador, M.A., Asuero, A.G., (1999) Talanta, 48, p. 729
  • Lober, A., Faber, N.K., Kowalski, B.R., (1997) Anal. Chem., 69, p. 1620
  • Haaland, D.M., Thomas, E.V., (1988) Anal. Chem., 60, p. 1193
  • Guillen, M.D., Cabo, N., (1997) J. Am. Oil Chem. Soc., 74, p. 1281
  • Geladi, P., MacDougall, D., Martens, H., (1985) Appl. Spectrosc., 39, p. 491
  • Naes, T., Isaksson, T., Fearn, T., Davies, T., (2002) A User Friendly Guide to Multivariate Calibration and Classification, , NIR Publications, Chichester, UK
  • Iñón, F.A., Garrigues, S., De La Guardia, M., (2002) Analyst, , in press
  • Isaksson, T., Naes, T., (1990) Appl. Spectrosc., 44, p. 1152
  • Olivieri, A.C., (2002), personal communication; Lober, A., (1986) Anal. Chem., 58, p. 1767
  • Boqué, R., Rius, F.X., (1996) Chemometrics and intelligent laboratory systems, 32, p. 11

Citas:

---------- APA ----------
Iñón, F.A., Garrigues, J.M., Garrigues, S., Molina-Díaz, A. & De La Guardia, M. (2003) . Selection of calibration set samples in determination of olive oil acidity by partial least squares-attenuated total reflectance-Fourier transform infrared spectroscopy. Analytica Chimica Acta, 489(1), 59-75.
http://dx.doi.org/10.1016/S0003-2670(03)00711-6
---------- CHICAGO ----------
Iñón, F.A., Garrigues, J.M., Garrigues, S., Molina-Díaz, A., De La Guardia, M. "Selection of calibration set samples in determination of olive oil acidity by partial least squares-attenuated total reflectance-Fourier transform infrared spectroscopy" . Analytica Chimica Acta 489, no. 1 (2003) : 59-75.
http://dx.doi.org/10.1016/S0003-2670(03)00711-6
---------- MLA ----------
Iñón, F.A., Garrigues, J.M., Garrigues, S., Molina-Díaz, A., De La Guardia, M. "Selection of calibration set samples in determination of olive oil acidity by partial least squares-attenuated total reflectance-Fourier transform infrared spectroscopy" . Analytica Chimica Acta, vol. 489, no. 1, 2003, pp. 59-75.
http://dx.doi.org/10.1016/S0003-2670(03)00711-6
---------- VANCOUVER ----------
Iñón, F.A., Garrigues, J.M., Garrigues, S., Molina-Díaz, A., De La Guardia, M. Selection of calibration set samples in determination of olive oil acidity by partial least squares-attenuated total reflectance-Fourier transform infrared spectroscopy. Anal. Chim. Acta. 2003;489(1):59-75.
http://dx.doi.org/10.1016/S0003-2670(03)00711-6