Artículo

Estamos trabajando para incorporar este artículo al repositorio
Consulte el artículo en la página del editor
Consulte la política de Acceso Abierto del editor

Abstract:

A flow injection system coupled to a photodiode array spectrophotometer (FI-PDA) for the multicomponent kinetic determination of Cu, Zn, Co, Ni and Fe at trace levels is presented. The substitution reaction of metal-nitrilotriacetic complexes (M-NTA) by 4-(2-pyridilazo) resorcinol (PAR) instead of the direct complexation of the free ions with PAR is employed. In this way, the spectral differences between the colored complexes are combined with the different reaction rates of the ions producing a more specific λ-time region for each metal enhancing the selectivity. Since the NTA-M-PAR system is fast and the pure analyte profiles appear partially overlapped in the time and λ-axis, temporal and spectral information were added to PLS and PCR models to improve results and to increase the number of metals to be determined. The developed method provides the fast and cheap determination of the five metals at the sub-ppm range and demonstrates that the use of temporal and spectral information increases the number of analytes to be simultaneously determined, improving the analytical figures of merit as well. © 2001 Elsevier Science B.V.

Registro:

Documento: Artículo
Título:Multicomponent kinetic determination of Cu, Zn, Co, Ni and Fe at trace levels by first and second order multivariate calibration
Autor:Fernández, F.M.; Tudino, M.B.; Troccoli, O.E.
Filiación:Laboratorio De Análisis De Trazas, Departamento De Quimica Inorganica, Analitica Y Quimica Fisica/INQUIMAE, Facultad De Ciencias Exactas Y Naturales, Capital Federal, Argentina
Palabras clave:Co; Cu; Fe; Figures of merit; Flow injection; Multicomponent kinetic determination; Multivariate calibration; Ni; PAR; Zn; cobalt; copper; iron; metal; nickel; nitrilotriacetic acid; resorcinol; zinc; article; calibration; chemical reaction; complex formation; flow injection analysis; flow kinetics; multivariate analysis; priority journal; reaction analysis; reaction time; spectrophotometry; Rickettsia sp. PAR
Año:2001
Volumen:433
Número:1
Página de inicio:119
Página de fin:133
DOI: http://dx.doi.org/10.1016/S0003-2670(00)01380-5
Título revista:Analytica Chimica Acta
Título revista abreviado:Anal. Chim. Acta
ISSN:00032670
CODEN:ACACA
CAS:cobalt, 7440-48-4; copper, 15158-11-9, 7440-50-8; iron, 14093-02-8, 53858-86-9, 7439-89-6; nickel, 7440-02-0; nitrilotriacetic acid, 139-13-9, 28528-44-1; resorcinol, 108-46-3; zinc, 7440-66-6, 14378-32-6
Registro:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_00032670_v433_n1_p119_Fernandez

Referencias:

  • Gemperline, P.J., (1989) J. Chemometr., 3, p. 549
  • Thomas, E.V., (1994) Anal. Chem., 66 (15), pp. 795A
  • Mottola, H.A., (1988) Kinetic Aspects of Analytical Chemistry, , Wiley, New York
  • Jordan, R.B., (1991) Reaction Mechanisms of Metallic and Organometallic Systems, , Oxford University Press, New York
  • Tanaka, M., Funashashi, S., Shirai, K., (1967) Anal. Chim. Acta, 39, p. 437
  • Engström, E., Karlberg, B., (1996) J. Chemometr., 10, p. 509
  • Engström, E., Jönebring, I., Karlberg, B., (1998) Anal. Chim. Acta, 371, p. 227
  • Azubel, M., Fernández, F.M., Tudino, M.B., Troccoli, O.E., (1999) Anal. Chim. Acta, 398, p. 93
  • Booksh, K.S., Kowalski, B.R., (1994) Anal. Chem., 66 (15), pp. 782A
  • Martens, H., Naes, T., (1989) Multivariate Calibration, , Wiley, New York
  • Sommer, L., Kubán, V., Langová, M., (1982) Fresenius Z. Anal. Chem., 310, p. 51
  • Bro, R., (1996) J. Chemometr., 10, p. 47
  • Massart, D.L., Vandeginste, B.G.M., Buydens, L.M.C., De Jong, S., Lewi, P.J., Smeyers-Verbeke, J., (1997) Handbook of Chemometrics and Qualimetrics, (PART B). , Elsevier, Amsterdam
  • Lorber, N.M., Faber, B.R., Kowalski, (1997) Anal. Chem., 69, p. 1620
  • Xu, L., Schechter, I., (1997) Anal. Chem., 69, p. 3722
  • Faber, N.M., (1998) Anal. Chem., 70, p. 5108
  • López-Cueto, G., Ostra, M., Ubide, C., (2000) Anal. Chim. Acta, 405, p. 285
  • Shuman, M.S., Shain, I., (1969) Anal. Chem., 41 (13), p. 1818
  • Valcárcel, M., Luque de Castro, M.D., (1987) Flow-Injection Analysis, , Ellis Horwood, Chichester
  • Linares, P., Luque de Castro, M.D., Valcarcel, M., (1985) Anal. Chem., 57, p. 2101
  • Betteridge, D., Fields, B., (1983) Z. Anal. Chem., 314, p. 386
  • Dahl, J.H., Espersen, D., Jensen, A., (1979) Anal. Chim. Acta, 105, p. 327
  • Boqué, R., Rius, F.X., (1996) Chemometr. Intell. Lab. Syst., 32, p. 11
  • Messick, N.J., Kalivas, J.H., Lang, P.M., (1996) Anal. Chem., 68, p. 1572
  • Faber, N.M., (1998) Anal. Chem., 70, p. 5108
  • Faber, N.M., Lorber, A., Kowalski, B.R., (1997) J. Chemometr., 11, p. 419
  • Lin, Z., Booksh, K.S., Burguess, L.W., Kowalski, B.R., (1994) Anal. Chem., 66, p. 2552
  • Gui, M., Rutan, S.C., Agbodjan, A., (1995) Anal. Chem., 67, p. 3293

Citas:

---------- APA ----------
Fernández, F.M., Tudino, M.B. & Troccoli, O.E. (2001) . Multicomponent kinetic determination of Cu, Zn, Co, Ni and Fe at trace levels by first and second order multivariate calibration. Analytica Chimica Acta, 433(1), 119-133.
http://dx.doi.org/10.1016/S0003-2670(00)01380-5
---------- CHICAGO ----------
Fernández, F.M., Tudino, M.B., Troccoli, O.E. "Multicomponent kinetic determination of Cu, Zn, Co, Ni and Fe at trace levels by first and second order multivariate calibration" . Analytica Chimica Acta 433, no. 1 (2001) : 119-133.
http://dx.doi.org/10.1016/S0003-2670(00)01380-5
---------- MLA ----------
Fernández, F.M., Tudino, M.B., Troccoli, O.E. "Multicomponent kinetic determination of Cu, Zn, Co, Ni and Fe at trace levels by first and second order multivariate calibration" . Analytica Chimica Acta, vol. 433, no. 1, 2001, pp. 119-133.
http://dx.doi.org/10.1016/S0003-2670(00)01380-5
---------- VANCOUVER ----------
Fernández, F.M., Tudino, M.B., Troccoli, O.E. Multicomponent kinetic determination of Cu, Zn, Co, Ni and Fe at trace levels by first and second order multivariate calibration. Anal. Chim. Acta. 2001;433(1):119-133.
http://dx.doi.org/10.1016/S0003-2670(00)01380-5