Artículo

Estamos trabajando para incorporar este artículo al repositorio
Consulte el artículo en la página del editor
Consulte la política de Acceso Abierto del editor

Abstract:

The insights provided by integrated detection (conductimetric) as a novel approach to follow physical dispersion in continuous-flow manifolds are presented. This approach replaces the conventional instantaneous detection and permits to follow the dispersion phenomena, including details of the radial component as the sample plug travels the manifold. Integrated detection permits to look at the radial dispersion in a detailed manner inaccessible to instantaneous detection. The effect of different experimental parameters affecting mass distribution was studied (e.g., flow rate, tube length and diameter, injected sample volume, and reactor type) and their effects on integrated response curves are discussed. A single channel manifold employing aqueous nitric acid as the conducting carrier, and water injected as sample plug, and playing the role of an insulator, provided the physicochemical model for the reported studies. Copyright (C) 1999 Elsevier Science B.V.

Registro:

Documento: Artículo
Título:Integrated conductimetric detection: Mass distribution in a dynamic sample zone inside a flow injection manifold
Autor:Andrade, F.J.; Iñon, F.A.; Tudino, M.B.; Troccoli, O.E.
Filiación:Lab. de Análisis de Trazas, Depto. Quim. Inorg., Analitica Y Q., 1428 Buenos Aires, Argentina
Palabras clave:Flow analysis; Integrated conductimetric detection; Physical dispersion; article; conductometry; flow injection analysis; instrument; priority journal; technique
Año:1999
Volumen:379
Número:1-2
Página de inicio:99
Página de fin:106
DOI: http://dx.doi.org/10.1016/S0003-2670(98)00557-1
Título revista:Analytica Chimica Acta
Título revista abreviado:Anal. Chim. Acta
ISSN:00032670
CODEN:ACACA
Registro:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_00032670_v379_n1-2_p99_Andrade

Referencias:

  • Rüzicka, J., Hansen, E.H., (1988) In: Flow Injection Analysis, 2nd Ed., Chapter 3, , Wiley, New York
  • Painton, C.C., Mottola, H.A., (1983) Anal. Chim. Acta, 154, p. 1
  • Ruzicka, J., Hansen, E.H., (1986) Anal. Chim. Acta, 179, p. 1
  • Delon Hull, R., Malick, R.E., Dorsey, J.G., (1992) Anal. Chim. Acta, 267, p. 1
  • Levenspiel, O., (1972) In: Chemical Reactor Engineering, 2nd Ed., Chapter 9, , Wiley, New York
  • Ruzicka, J., Hansen, E.H., (1975) Anal. Chim. Acta, 78, p. 145
  • Taylor, G., (1953) Proc. Roy. Soc. London a, 219, p. 86
  • Taylor, G., (1962) Proc. Roy. Soc. London a, 269, p. 352
  • Betteridge, D., (1978) Anal. Chem., 50, pp. 832A
  • Tijssen, R., (1980) Anal. Chim. Acta, 114, p. 71
  • Reijn, J.M., Van Der Linden, W.E., Poppe, H., (1980) Anal. Chim. Acta, 114, p. 105
  • Painton, C.C., Mottola, H., (1981) Anal. Chem., 53, p. 1713
  • Vanderslice, J., Stewart, K., Rosenfeld, G., (1981) Talanta, 28, p. 11
  • Painton, C.C., Mottola, H.A., (1984) Anal. Chim. Acta, 158, p. 67
  • Vanderslice, J.T., Stewart, K., Rosenfeld, G., Higgs, D., (1981) Talanta, 28, p. 11
  • Vanderslice, J.T., Rosenfeld, G., Beecher, G., (1986) Anal. Chim. Acta, 179, p. 119
  • Kolev, S.D., Pungor, E., (1986) Anal. Chim. Acta, 185, p. 315
  • Korenga, T., Yoshida, H., Yokota, Y., Kaseno, S., Takahashi, T., (1986) J. Flow Injection Anal., 3, p. 91
  • Bysouth, S.R., Tyson, J.F., (1992) Anal. Chim. Acta, 261, p. 549
  • Kolev, S.D., Van Der Linden, W.E., (1993) Int. J. Heat Mass Transfer, 36, p. 135
  • Matousek De Abel De La Cruz, A., Burguera, J.L., Burguera, M., Rivas, C., (1995) Talanta, 42, p. 701
  • Li, Y., Ma, H., (1995) Talanta, 42, p. 2033
  • Poppe, H., (1983) Anal. Chim. Acta, 145, p. 17
  • Johnson, B., Malick, R., Dorsey, J., (1992) Talanta, 39, p. 35
  • Wentzell, P.D., Bowdrige, M., Taylor, E., MacDonald, C., (1993) Anal. Chim. Acta, 278, p. 293
  • Andreev, V.P., Khidekel, M.I., (1993) Anal. Chim. Acta, 278, p. 307
  • Kolev, S.D., (1995) Anal. Chim. Acta, 308, p. 36
  • Spence, D.M., Crouch, S.R., (1997) Anal. Chem., 60, p. 573
  • Moring, S.E., Reel, R.T., Van Soest, R.E.J., (1993) Anal. Chem., 65, p. 3454
  • Van Der Linden, W.E., (1989) Flow Injection Atomic Spectroscopy, Chapter 2, , in: J.L. Burguera (Ed.), Marcel Dekker, New York
  • Valcarcel, M., Luque De Castro, M.D., (1987) In: Flow-Injection Analysis: Principles and Applications, Chapter 3, , Wiley/Ellis Horwood, New York/Chichester, UK
  • Narusawa, Y., Miyamae, Y., (1994) Anal. Chim. Acta, 296, p. 129
  • Stevens, T., Davies, J., Small, H., (1982) Anal. Chem., 53, p. 1488
  • Zagatto, E.A., Krug, F.J., Bergamin, H.F., Jorgensen, S.S., Dos Reis, B.F., (1979) Anal. Chim. Acta, 104, p. 279
  • Taylor, D., Nieman, T., (1984) Anal. Chim. Acta, 159, p. 397
  • Ananthakrishnan, V., Gill, W.N., Bardun, A.J., (1965) J. Am. Inst. Chem. Eng., 11, p. 1063

Citas:

---------- APA ----------
Andrade, F.J., Iñon, F.A., Tudino, M.B. & Troccoli, O.E. (1999) . Integrated conductimetric detection: Mass distribution in a dynamic sample zone inside a flow injection manifold. Analytica Chimica Acta, 379(1-2), 99-106.
http://dx.doi.org/10.1016/S0003-2670(98)00557-1
---------- CHICAGO ----------
Andrade, F.J., Iñon, F.A., Tudino, M.B., Troccoli, O.E. "Integrated conductimetric detection: Mass distribution in a dynamic sample zone inside a flow injection manifold" . Analytica Chimica Acta 379, no. 1-2 (1999) : 99-106.
http://dx.doi.org/10.1016/S0003-2670(98)00557-1
---------- MLA ----------
Andrade, F.J., Iñon, F.A., Tudino, M.B., Troccoli, O.E. "Integrated conductimetric detection: Mass distribution in a dynamic sample zone inside a flow injection manifold" . Analytica Chimica Acta, vol. 379, no. 1-2, 1999, pp. 99-106.
http://dx.doi.org/10.1016/S0003-2670(98)00557-1
---------- VANCOUVER ----------
Andrade, F.J., Iñon, F.A., Tudino, M.B., Troccoli, O.E. Integrated conductimetric detection: Mass distribution in a dynamic sample zone inside a flow injection manifold. Anal. Chim. Acta. 1999;379(1-2):99-106.
http://dx.doi.org/10.1016/S0003-2670(98)00557-1