Abstract:

In this work, a direct in-flow methodology for the acquisition of excitation-emission fluorescence matrices is presented. The system is particularly suited for measurements in the order of tens of milliseconds. A light source operated in continuous mode is dispersed through a grating and focused onto a square-section capillary. Under the spatially resolved excitation, the emission is collected, dispersed through a second grating and further focused onto a CCD array sensor. To allow the wavelength accuracy, a spectral calibration was performed registering the scattering signal of a dispersive element using interference filters ranging from 340 nm to 740 nm. The theoretical performance of the method was analyzed and second-order data obtained for different analyte mixtures are presented and discussed. PARAFAC was applied to evaluate the trilinearity of the obtained data. Mathematical evaluation by means of the criterion of similarity corroborates the agreement between experimental pure spectra and spectral profiles retrieved from PARAFAC. Moreover, the feasibility of the spectrometer to obtain second-order data for analyses with quantitative aims was demonstrated. Finally, fast data acquisition was proved by monitoring a chromatographic analysis of dye mixtures for the generation of third-order LC-EEM data. Here, an improvement in the resolution of the different instrumental modes was demonstrated. © 2018 Elsevier B.V.

Registro:

Documento: Artículo
Título:Multiway analysis through direct excitation-emission matrix imaging
Autor:Alcaraz, M.R.; Morzán, E.; Sorbello, C.; Goicoechea, H.C.; Etchenique, R.
Filiación:Departamento de Química Inorgánica, Analítica y Química Física, INQUIMAE, Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires, Intendente Güiraldes 2160, Ciudad Universitaria, Pabellón 2, Buenos Aires, C1428EGA, Argentina
Laboratorio de Desarrollo Analítico y Quimiometría (LADAQ), Cátedra de Química Analítica I, Facultad de Bioquímica y Ciencias Biológicas, Universidad Nacional del Litoral, Ciudad Universitaria, Santa Fe, S3000ZAA, Argentina
Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Godoy Cruz, 2290, Buenos Aires, C1425FQB, Argentina
Comisión Nacional de Energía Atómica, General Paz 1499, Buenos Aires, B1650KNA, Argentina
Palabras clave:Chemometrics; Excitation-emission matrix; Higher-order data analysis; Imaging; Charge coupled devices; Chromatographic analysis; Data acquisition; Imaging techniques; Light sources; Mixtures; Chemometrics; Excitation emission fluorescence; Excitation emission matrices; Fast data acquisition; Higher-order; Interference filters; Spectral calibration; Theoretical performance; Matrix algebra; accuracy; algorithm; Article; calculation; calibration; excitation emission matrix imaging; image analysis; imaging; light; liquid chromatography; luminance; mathematical analysis; measurement; Parallel factor analysis; priority journal; reliability; validity
Año:2018
Volumen:1032
Página de inicio:32
Página de fin:39
DOI: http://dx.doi.org/10.1016/j.aca.2018.07.069
Título revista:Analytica Chimica Acta
Título revista abreviado:Anal. Chim. Acta
ISSN:00032670
CODEN:ACACA
Registro:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_00032670_v1032_n_p32_Alcaraz

Referencias:

  • Lakowicz, J.R., Instrumentation for Fluorescence Spectroscopy, in Principles of Fluorescence Spectroscopy (2006), pp. 27-61. , Springer US New York, US; Kumar, K., Tarai, M., Mishra, A.K., Unconventional steady-state fluorescence spectroscopy as an analytical technique for analyses of complex-multifluorophoric mixtures, TrAC (2017) Trends Anal. Chem., 97, pp. 216-243
  • Temiz, H.T., Tamer, U., Berkkan, A., Boyaci, I.H., Synchronous fluorescence spectroscopy for determination of tahini adulteration (2017) Talanta, 167, pp. 557-562
  • Insausti, M., de Araújo Gomes, A., Camiña, J.M., Ugulino de Araújo, M.C., Fernández Band, B.S., Fluorescent fingerprints of edible oils and biodiesel by means total synchronous fluorescence and Tucker3 modeling (2017) Spectrochim. Acta a Mol. Biomol. Spectrosc., 175, pp. 185-190
  • Cheng, C., Wu, J., You, L., Tang, J., Chai, Y., Liu, B., Khan, M.F.S., Novel insights into variation of dissolved organic matter during textile wastewater treatment by fluorescence excitation emission matrix (2018) Chem. Eng. J., 335, pp. 13-21
  • Mbogning Feudjio, W., Ghalila, H., Nsangou, M., Mbesse Kongbonga, Y.G., Majdi, Y., Excitation-emission matrix fluorescence coupled to chemometrics for the exploration of essential oils (2014) Talanta, 130, pp. 148-154
  • Pagani, A.P., Ibañez, G.A., Four-way calibration applied to the processing of pH-modulated fluorescence excitation-emission matrices. Analysis of fluoroquinolones in the presence of significant spectral overlapping (2017) Microchem. J., 132, pp. 211-218
  • Carabajal, M.D., Arancibia, J.A., Escandar, G.M., On-line generation of third-order liquid chromatography–excitation-emission fluorescence matrix data. Quantitation of heavy-polycyclic aromatic hydrocarbons (2017) J. Chromatogr. A, 1527, pp. 61-69
  • Montemurro, M., Pinto, L., Véras, G., de Araújo Gomes, A., Culzoni, M.J., Ugulino de Araújo, M.C., Goicoechea, H.C., Highly sensitive quantitation of pesticides in fruit juice samples by modeling four-way data gathered with high-performance liquid chromatography with fluorescence excitation-emission detection (2016) Talanta, 154, pp. 208-218
  • Trevisan, M., Poppi, R.J., Determination of doxorubicin in human plasma by excitation-emission matrix fluorescence and multi-way analysis (2003) Anal. Chim. Acta, 493, pp. 69-81
  • Azcarate, S.M., de Araújo Gomes, A., Alcaráz, M.R., Ugulino de Araújo, M.C., Camiña, J.M., Goicoechea, H.C., Modeling excitation-emission fluorescence matrices with pattern recognition algotirhms for classification of Argenine white wines according grape variety (2015) Food Chem., 184, pp. 214-219
  • Escandar, G.M., Olivieri, A.C., Faber, N.M., Goicoechea, H.C., Muñoz de la Peña, A., Poppi, R.J., Second- and third-order multivariate calibration: data, algorithms and applications (2007) TrAC Trends Anal. Chem. (Reference Ed.), 26, pp. 752-765
  • Escandar, G.M., Goicoechea, H.C., Muñoz de la Peña, A., Olivieri, A.C., Second- and higher-order data generation and calibration: a tutorial (2014) Anal. Chim. Acta, 806, pp. 8-26
  • Olivieri, A.C., Escandar, G.M., Practical Three-way Calibration (2014), Elsevier Waltham, USA; Montemurro, M., Siano, G.G., Culzoni, M.J., Goicoechea, H.C., Automatic generation of photochemically induced excitation-emission-kinetic four-way data for the highly selective determination of azinphos-methyl in fruit juices (2017) Sensor. Actuator. B Chem., 239, pp. 397-404
  • Carabajal, M.D., Arancibia, J.A., Escandar, G.M., Excitation-emission fluorescence-kinetic data obtained by Fenton degradation. Determination of heavy-polycyclic aromatic hydrocarbons by four-way parallel factor analysis (2017) Talanta, 165, pp. 52-63
  • Sorbello, C., Etchenique, R., Intrinsic optical sectioning with upconverting nanoparticles (2018) Chem. Commun., 54, pp. 1861-1864
  • Muroski, A.R., Booksh, K.S., Myrick, M.L., Single-measurement excitation/emission matrix spectrofluorometer for determination of hydrocarbons in ocean water. 1. Instrumentation and background correction (1996) Anal. Chem., 68, pp. 3534-3538
  • Booksh, K.S., Muroski, A.R., Myrick, M.L., Single-measurement excitation/emission matrix spectrofluorometer for determination of hydrocarbons in ocean water. 2. Calibration and quantitation of naphthalene and styrene (1996) Anal. Chem., 68, pp. 3539-3544
  • Peng, L., Gardecki, J.A., Bouma, B.E., Tearney, G.J., Fourier fluorescence spectrometer for excitation emission matrix measurement (2008) Optic Express, 16, pp. 10493-10500
  • Yuan, J., Peng, L., Bouma, B.E., Tearney, G.J., Quantitative FRET measurement by high-speed fluorescence excitation and emission spectrometer (2010) Optic Express, 18, pp. 18839-18851
  • Andrews, N.L.P., Ferguson, T., Rangaswamy, A.M.M., Bernicky, A.R., Henning, N., Dudelzak, A., Reich, O., Loock, H.P., Hadamard-transform fluorescence excitation-emission-matrix spectroscopy (2017) Anal. Chem., 89, pp. 8554-8564
  • (2010) Matlab, , MathWorks Inc Natick, MA, Estados Unidos
  • Gómez, V., Miró, M., Callao, M.P., Cerdà, V., Coupling of sequential injection chromatography with multivariate curve resolution-alternating least-squares for enhancement of peak capacity (2007) Anal. Chem., 79, pp. 7767-7774
  • Amigo, J.M., Marini, F., Chapter 7-Multiway methods (2013) Data Handling in Science and Technology, pp. 265-313. , M. Federico Elsevier
  • Bro, R., PARAFAC. Tutorial and applications (1997) Chemometr. Intell. Lab. Syst., 38, pp. 149-171
  • Boqué Martí, R., Ferré Baldrich, J., Chapter 1-fundamentals of PARAFAC (2015) Data Handling in Science and Technology, pp. 7-35. , A. Muñoz de la Peña H.C. Goicoechea G.M. Escandar A.C. Olivieri Elsevier
  • Olivieri, A.C., Escandar, G.M., Chapter 7-parallel factor analysis: nontrilinear data of type 1 (2014) Practical Three-way Calibration, pp. 109-125. , Elsevier Boston
  • Montemurro, M., Siano, G.G., Alcaráz, M.R., Goicoechea, H.C., Third order chromatographic-excitation–emission fluorescence data: advances, challenges and prospects in analytical applications (2017) TrAC Trends Anal. Chem. (Reference Ed.), 93, pp. 119-133
  • Alcaráz, M.R., Bortolato, S., Goicoechea, H.C., Olivieri, A.C., A new modeling strategy for third-order fast high-performance liquid chromatographic data with fluorescence detection. Quatitation of fluoroquinolones in water samples (2015) Anal. Bioanal. Chem., 407, pp. 1999-2011
  • Bortolato, S.A., Lozano, V.A., Muñoz de la Peña, A., Olivieri, A.C., Novel augmented parallel factor model for four-way calibration of high-performance liquid chromatography–fluorescence excitation–emission data (2015) Chemometr. Intell. Lab. Syst., 141, pp. 1-11
  • Alcaráz, M.R., Siano, G.G., Culzoni, M.J., Munoz de la Pena, A., Goicoechea, H.C., Modeling four and three-way fast high-performance liquid chromatography with fluorescence detection data for quiatitation of fluoroquinolones in water samples (2014) Anal. Chim. Acta, 809, pp. 37-46
  • Lozano, V.A., Muñoz de la Peña, A., Durán-Merás, I., Espinosa Mansilla, A., Escandar, G.M., Four-way multivariate calibration using ultra-fast high-performance liquid chromatography with fluorescence excitation–emission detection. Application to the direct analysis of chlorophylls a and b and pheophytins a and b in olive oils (2013) Chemometr. Intell. Lab. Syst., 125, pp. 121-131

Citas:

---------- APA ----------
Alcaraz, M.R., Morzán, E., Sorbello, C., Goicoechea, H.C. & Etchenique, R. (2018) . Multiway analysis through direct excitation-emission matrix imaging. Analytica Chimica Acta, 1032, 32-39.
http://dx.doi.org/10.1016/j.aca.2018.07.069
---------- CHICAGO ----------
Alcaraz, M.R., Morzán, E., Sorbello, C., Goicoechea, H.C., Etchenique, R. "Multiway analysis through direct excitation-emission matrix imaging" . Analytica Chimica Acta 1032 (2018) : 32-39.
http://dx.doi.org/10.1016/j.aca.2018.07.069
---------- MLA ----------
Alcaraz, M.R., Morzán, E., Sorbello, C., Goicoechea, H.C., Etchenique, R. "Multiway analysis through direct excitation-emission matrix imaging" . Analytica Chimica Acta, vol. 1032, 2018, pp. 32-39.
http://dx.doi.org/10.1016/j.aca.2018.07.069
---------- VANCOUVER ----------
Alcaraz, M.R., Morzán, E., Sorbello, C., Goicoechea, H.C., Etchenique, R. Multiway analysis through direct excitation-emission matrix imaging. Anal. Chim. Acta. 2018;1032:32-39.
http://dx.doi.org/10.1016/j.aca.2018.07.069