A method is proposed for wavelength calibration of the reversed-optics polychromators of photodiode array spectrophotometers. The central wavelength of each diode is determined using classical line emission sources and an appropriate algorithm. The method can be used even when the light from the slit image formed on the detector falls on several diodes, whether due to a large slit to diode ratio, detector window effects or other causes.

Registro:

Documento: Artículo
Título:Ultraviolet-visible photodiode array spectrophotometer wavelength calibration method. A practical computer algorithm
Autor:Berlot, P.E.; Locascio, G.A.
Filiación:Laboratory of Biological Instrumentation, University of Buenos Aires, Ciudad Universitaria, CP 1428, Buenos Aires, Argentina
Palabras clave:article; chemical analysis; computer system; spectrophotometry; technique
Año:1991
Volumen:116
Número:3
Página de inicio:313
Página de fin:316
DOI: http://dx.doi.org/10.1039/AN9911600313
Título revista:The Analyst
ISSN:00032654
Registro:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_00032654_v116_n3_p313_Berlot

Referencias:

  • (1987) Standard Method for Describing and Measuring Performance of Ultraviolet, Visible and Near Infrared Spectrophotometen, Annual Book of ASTM Standards, p. 408. , vol. 14.01, 1987, E 275–83, American Society for Testing and Materials (ASTM), Philadelphia, PA
  • (1981) Standards in Absorption Spectrometry, p. 130. , Burgess, C., and Knowles, A., Chapman and Hall, London and New York
  • Mavrodineanu, R., (1975) NBS Spec. Publ. 260-51, pp. 54-64. , Washington, DC
  • (1987) Advances in Standards and Methodology in Spectrophotometry, , Burgess, C., and Mielenz, K. D., Elsevier, Amsterdam, pp. 99, 125 and 303
  • (1987) Standard Practice for the Periodic Calibration of Narrow Band-Pass Spectrophotometers, Annual Book of ASTM Standards, p. 824. , vol. 14.01, 1987, E 925–83, American Society for Testing and Materials (ASTM), Philadelphia, PA
  • McNeirney, J., Slavin, M., (1962) Appl. Opt., 1, p. 365
  • (1984) Practical Absorption Spectrometry, p. 221. , Knowles, A., and Burgess, C., Chapman and Hall, London and New York
  • Burgess, C., (1977) UV Spectrom. Group Bull., 5, p. 77
  • Fog, J., Osnes, E., (1962) Analyst, 87, p. 760

Citas:

---------- APA ----------
Berlot, P.E. & Locascio, G.A. (1991) . Ultraviolet-visible photodiode array spectrophotometer wavelength calibration method. A practical computer algorithm. The Analyst, 116(3), 313-316.
http://dx.doi.org/10.1039/AN9911600313
---------- CHICAGO ----------
Berlot, P.E., Locascio, G.A. "Ultraviolet-visible photodiode array spectrophotometer wavelength calibration method. A practical computer algorithm" . The Analyst 116, no. 3 (1991) : 313-316.
http://dx.doi.org/10.1039/AN9911600313
---------- MLA ----------
Berlot, P.E., Locascio, G.A. "Ultraviolet-visible photodiode array spectrophotometer wavelength calibration method. A practical computer algorithm" . The Analyst, vol. 116, no. 3, 1991, pp. 313-316.
http://dx.doi.org/10.1039/AN9911600313
---------- VANCOUVER ----------
Berlot, P.E., Locascio, G.A. Ultraviolet-visible photodiode array spectrophotometer wavelength calibration method. A practical computer algorithm. 1991;116(3):313-316.
http://dx.doi.org/10.1039/AN9911600313